IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx QPS 14.0004X issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2014-04-15 Page 1 of 3


    
Applicant:
Hebeler Corporation
2000 Military Road
Tonawanda, NY 14150
United States of America


 
Equipment:Model 24184A -000 A116 Syngas Module; Serial Number 02/2014-A116
Optional accessory:


 
Type of Protection:Ex d e em nA nC IIB+H2 T2 Gc


 
Marking:

Model No. 24184A -000

Serial No. 02/2014-A116

Ex d e em nA nC IIB+H2 T2 Gc 

Tamb = -20C to +55C

IECEx QPS 14.0004X 

 
Approved for issue on behalf of the IECEx
Certification Body:
Alfonso Mattucci

 
Position:QA Engineer


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
QPS
Evaluation Services Inc.
81 Kelfield St
Unit 8
Toronto, Ontario M9W 5A3
Canada


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx QPS 14.0004X
 
Date of Issue:2014-04-15Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Hebeler Corporation
2000 Military Road
Tonawanda, NY 14150
United States of America


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2000
Edition: 3.1
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
CA/QPS/ExTR14.0003/00


Quality Assessment Report:

US/UL/QAR11.0007/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx QPS 14.0004X
 
Date of Issue:2014-04-15Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Model No. 24184A -000 A116 Syngas Module.  Electrical ratings 480Vac, 1-Ph, 60Hz / 220V, 1-Ph, 60Hz / 125Vdc / 24Vdc

The A116 Syngas Module is a component part of an electrical generator assembly manufactured by General Electric Power & Water Division; USA.  All Ex equipment and components within the hazardous classified area of the  A116 Syngas module are IEC Ex certified.

Enclosures and junction boxes in the A116 Syngas module clearly presents instructions for wiring interconnections and field wiring during final installation of equipment. Instructions for safety, putting into service; use; assembling and dismantling; maintenance, overhaul and repair; Installation; adjustment; refer to installation instructions and drawings for guidance

The A116 Syngas module contains the gas piping and main control valves used to control the flow, pressure, and distribution of fuel to the turbine combustor. 

The module contains valves and instrumentation for both control of Natural Gas fuel and a Syngas fuel source as well as Nitrogen Diluent, Compressor Discharge Purge, and Nitrogen Purge. Additionally the module contains equipment for fire protection/suppression, lighting, ventilation, and gas monitoring system. 

The A116 module is not a standalone system and is not functional until it is properly installed in the gas turbine power plant. 

 

NOTE: Although this equipment is covered under a Full Certificate supported by the ExTR and QAR listed, each unit is inspected and verified by the ExCB upon completion. This Certificate covers only the Model Number and Serial Number listed in the “Electrical Apparatus” section on page 1 of this Certificate.

 

 

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 

1) The Area classification drawing, No 104T9532 defines the boundaries between various hazardous areas within the A116 Syngas Module and the associated non-hazardous zones. It is the responsibility of the end user of equipment to maintain the hazardous area envelop as defined in the drawing No 104T9532 in accordance with area classifications procedures from IEC 60079-10-1

 

2) Ex “d” components provided with a rigid conduit seal shall be sealed during assembly, field installation and commissioning of the equipment. A list of seals informing location and quantities was supplied with equipment.  All Ex “d “ components within the hazardous classified area of A116 Syngas module shall be re-inspected by local recognized certifier body and/or the local authority jurisdiction previous equipment being fully functional for operation.  

 

3) Components ID 33PG-13C; 33PG-14O/C; 33VS7-1/2; and 33VN-1; Switch pack manufactured by TopWorx:

 

- The air pressure to the valve block, when fitted, shall not exceed 10.0 bar.

- The slotted hexagonal head cover screws are not of standard form; they shall only be replaced with identical screws sourced from the equipment manufacturer.

- The hexagonal head cover screws are to be replaced only with stainless steel A2-70 or A4-80 screws to ISO 35061.

- Cover fasteners are to be tightened to a torque value of 10.85 Nm (8ft/lbs) minimum.

 

4) Component Tag Number ID 20 NC-1 , Solenoid Valve mounted on VNC-1 Control Valve: Short Circuit fault protection shall be provided by the end user. See special conditions of use in certificate IEC Ex PTB 07.0021X.

 

 







Copyright © IEC-IECEx 2017 , Geneva Switzerland. All rights reserved.