Ex COMPONENT CERTIFICATE

 
Certificate No.:
IECEx IBE 09.0016U issue No.: 5
 
Status:
Current
 
Date of Issue:2018-12-05Page 1 of 4
 
 
Applicant:
BARTEC VARNOST d.o.o.
Cesta 9.avgusta 59
1410 Zagorje ob Savi
Slovenia
Ex Component: Empty enclosures and cubicles of type 07-56.1-..../.... and 07-55.1-..../....
This component is NOT intended to be used alone and requires additional consideration when incorporated into other equipment or systems for
use in explosive atmospheres (refer to IEC 60079-0).
 
 
Type of Protection:Increased Safety "e" and dust ignition protection by enclosure "t"

 Marking:

Ex eb IIC Gb
Ex tb IIIC Db

 
 
Approved for issue on behalf of the IECEx
Certification Body:
Dipl.-Ing. Alexander Henker

 
Position:Deputy Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
IBExU Institut für Sicherheitstechnik GmbH
Certification Body
Fuchsmühlenweg 7
09599 Freiberg
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx IBE 09.0016U
 
Date of Issue:2018-12-05Issue No.: 5
 
Page 2 of 4
  
Manufacturer:
BARTEC VARNOST d.o.o.
Cesta 9.avgusta 59
1410 Zagorje ob Savi
Slovenia


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex Component covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The Ex Component and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
IEC 60079-7 : 2015
Edition: 5.0
Explosive atmospheres – Part 7: Equipment protection by increased safety ''e''
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the Ex Component listed has successfully met the examination and test requirements as recorded in

 
Test Report:

DE/IBE/ExTR09.0014/00DE/IBE/ExTR09.0014/01DE/IBE/ExTR09.0014/02DE/IBE/ExTR09.0014/03DE/IBE/ExTR09.0014/04


Quality Assessment Report:

DE/TUN/QAR06.0017/10IT/CES/QAR12.0006/05NL/DEK/QAR11.0034/04NL/DEK/QAR12.0059/04NL/DEK/QAR12.0061/06NO/NEM/QAR07.0003/11SI/SIQ/QAR11.0003/04


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx IBE 09.0016U
 
Date of Issue:2018-12-05Issue No.: 5
 
Page 3 of 4
 
Schedule
 
   Ex Component(s) covered by this certificate is described below:
 

Empty enclosures and cubicles of type 07-56.1-..../.... and 07-55.1-..../.... are made of stainless steel and serve for the installation of components. They may be provided with flanges and inspection windows.

For technical data as well as additional manufacturing locations see Annex.

 
 
   SCHEDULE OF LIMITATIONS:
 

The service temperature range depends on the gasket used and has to be met. The service temperature range may be limited if the empty enclosures contain a plastic window.

Types including plastic inspection windows exceeding 20 cm² (IIC) or 100 cm² (IIB, IIA) require a warning label according to IEC 60079-0, Clause 29.12 g).

 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx IBE 09.0016U
 
Date of Issue:2018-12-05Issue No.: 5
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 
  • The empty enlcosures comply with the requirements of IEC 60079-7, Ed. 5 and IEC 60079-31, Ed. 2.
  • New types including new gaskets have been added.
  • New manufacturing locations have been added.
 
 