IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx SIR 12.0017X issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2012-03-30 Page 1 of 3


    
Applicant:
Joy Mining Machinery
Thorn Hill Industrial Park
177 Thorn Hill Road
Warrendale
Pennsylvania 15086
United States of America


 
Electrical Apparatus:Power and Control Connection Box Type 5100006855
Optional accessory:


 
Type of Protection:Flameproof


 
Marking:

Ex d I Mb

 
Approved for issue on behalf of the IECEx
Certification Body:
C Ellaby

 
Position:Deputy Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 12.0017X
 
Date of Issue:2012-03-30Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Joy Mining Machinery
Thorn Hill Industrial Park
177 Thorn Hill Road
Warrendale
Pennsylvania 15086
United States of America


 
 Additional Manufacturing location(s):

These products may be manufactured at any Joy Mining Facility listed on Quality Assessment Report GB/SIR/QAR07.0007/02 that has been audited for the manufacture of the type of protection listed.
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/SIR/ExTR12.0075/00


Quality Assessment Report:

GB/SIR/QAR07.0007/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 12.0017X
 
Date of Issue:2012-03-30Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The type 5100006855 Power and Control Connection Enclosure is constructed from steel and has a bolt on front access cover.  The equipment is rated for 3300 V, three phase, 400 A maximum current. There is an external handle, with an operating rod passing through the enclosure wall, to facilitate the resetting of an internal circuit breaker; the handle can either be mounted to the top or side of the enclosure.  The enclosure has plain gland entries, which are to be populated with suitably approved cable glands, it also houses terminal connection strips, a fuse block and a DC converter.  The lid is secured with fourteen, M12 x 30, Cap screws that are all 10.9 property class or above.
 
Conditions of manufacture
The Manufacturer shall comply with the following:
1. Each enclosure shall be subjected to a routine overpressure of at least 10.77 bar for at least 10 s, as required by clause 16.1 of IEC/EN60079-1. There shall be no permanent deformation or damage to the enclosure.
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

1

The 5100006855 power and control connection enclosure has minimum joint widths (L) and maximum constructional gaps (ic) other than the relevant minimum/maximum required by table 1 of IEC 60079-1. Contact the manufacturer for information on the dimensions of the flame proof joints.
 







Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.