Certificate No.:
IECEx BAS 06.0032 issue No.:2
 
Status:
Current
 
Date of Issue:2015-06-17 Page 1 of 4


    
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Equipment:Type KCD0-SD-Ex1.1245* Transformer Isolated Solenoid Driver
Optional accessory:


 
Type of Protection:Intrinsic Safety


 
Marking: [Ex ia Ga] IIC
[Ex ia Da] IIIC
[Ex ia Ma] I
(-20°C ≤ Ta ≤ +60°C)
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:Technical Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 06.0032
 
Date of Issue:2015-06-17Issue No.: 2
 
Page 2 of 4
 
 Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs (Manufacturing) PTE LTD
18 Ayer Rajah Crescent
Singapore 139942
Singapore
PT. Pepperl + Fuchs
Bintan
SD 56, 57 Lobam, Bintan Industrial Estate
IND-Pulau Bintan
Riau
Indonesia
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR06.0047/00GB/BAS/ExTR12.0043/00GB/BAS/ExTR15.0178/00


Quality Assessment Report:

DE/PTB/QAR06.0007/03DE/PTB/QAR06.0008/06


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 06.0032
 
Date of Issue:2015-06-17Issue No.: 2
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Type KCD0-SD-Ex1.1245* Transformer Isolated Solenoid Driver is designed to transfer current from unspecified apparatus located in the non-hazardous area to the hazardous area. The voltage and current passed to the hazardous area are limited to intrinsically safe levels and have linear characteristics. The hazardous area circuit is galvanically isolated from the non-hazardous area circuit using transformers.

The Type KCD0-SD-Ex1.1245* Transformer Isolated Solenoid Driver comprise a number of electronic components, including an isolating transformer, fuses, zener diodes and resistors all mounted on a single printed circuit board and housed in a plastic enclosure with polarised plug-in terminals or optional spring terminals (.SP types only) for hazardous and non-hazardous area connections. LED indication is provided for channel status.

The variants covered by this certificate are as follows:
KCD0-SD-Ex1.1245
KCD0-SD-Ex1.1245.SP
KCD0-SD-Ex1.1245-Y*
KCD0-SD-Ex1.1245.SP-Y*

See Annex for electrical parameters (all variants).

 
SPECIFIC CONDITIONS OF USE: NO
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 06.0032
 
Date of Issue:2015-06-17Issue No.: 2
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Variation 2.1

To permit minor changes to the transformer.


Variation 2.2

To confirm that the equipment covered by this certificate has been reviewed against the requirements of IEC 60079-0: 2011 Ed 6 and IEC 60079-11: 2011 Ed 6 in respect of the differences from IEC 60079-0: 2007 Ed 5 and IEC 60079-11: 2006 Ed 5 and that none of these differences affect this equipment. The equipment is already marked in accordance with the requirements of these Standards.

 ExTR:  GB/BAS/ExTR15.0178/00 File Reference:   15/0356
 
 