Certificate No.:
IECEx BAS 08.0059 issue No.:1
 
Status:
Current
 
Date of Issue:2008-12-15 Page 1 of 4


    
Applicant:
Pepperl & Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Equipment:Transformer Isolated, Loop Powered, Current Separator Type KFD0-CS-Ex*.52
Optional accessory:


 
Type of Protection:Intrinsic Safety [ia] [iaD]


 
Marking: [Zone 0] [Ex ia] IIC
[Ex ia] I
[Ex iaD]
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:Managing Director


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0059
 
Date of Issue:2008-12-15Issue No.: 1
 
Page 2 of 4
 
 Manufacturer:
Pepperl & Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl & Fuchs (Manufacturing) Pvt Limited
Pepperl & Fuchs Building
18 Ayer Rajah Creacent
0513
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2004
Edition: 1
Electrical apparatus for explosve gas atmospheres - Part 26: Construction, test and marking of Group II Zone 0 electrical apparatus
IEC 61241-11 : 2005
Edition: 1
Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'iD'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR08.0116/00


Quality Assessment Report:

DE/PTB/QAR06.0007/01DE/PTB/QAR06.0008/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0059
 
Date of Issue:2008-12-15Issue No.: 1
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Transformer Isolated, Loop Powered, Current Separator Type KFD0-CS-Ex*.52 is designed to restrict the transfer of energy from unspecified Non Hazardous Area Apparatus  to Hazardous Area Apparatus without the need for a high integrity earth. The unit is intended to provide a 4-20mA signal return path from the hazardous area and both a dual and a single channel version is available.

The “*” in the type number is replaced by a “2” for the dual channel version and a “1” for the single channel version.

The apparatus is designed for a rated input voltage not exceeding 40V d.c. but the creepage and clearance distances between the non hazardous area and the hazardous area circuitry are acceptable for a peak voltage of 375 volts, (253V volts r.m.s.)

The apparatus comprises a maximum of two channels, and each channel comprises a transformer and electronic components mounted on a printed circuit board and housed within a plastic enclosure which is fitted with terminals for the connection of external equipment.

S
ee Annex for electrical parameters.

 
SPECIFIC CONDITIONS OF USE: NO
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0059
 
Date of Issue:2008-12-15Issue No.: 1
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Variation 1.1

To permit a change to the Annex not affecting the intrinsic safety assessment. 
The Annex is now at Issue 1.

 

 
 