IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx SIR 09.0020X issue No.:5
 
Status:
Current
 
Date of Issue:2010-07-13 Page 1 of 5


    
Applicant:
ADS Environmental Services
4940 Research Drive
Huntsville
Alabama 35805
United States of America


 
Electrical Apparatus:Flowshark Triton (Model Number 8000-FST) or Flowhawk (Model Number 8000-FHK)
Optional accessory:


 
Type of Protection:Intrinsic Safety


 
Marking: Flowshark Triton (8000-FST), Flowhawk (8000-FHK), Combo Sensor P/N 8K-CS1, Combo Sensor P/N 8K-CS2, Combo Sensor P/N 8K-CS3
Ex ia IIB T4 Ga
Direct Connect Interface Unit P/N 8000-0054 (fitted in the Safe Area)
[Ex ia] IIB (Ga)
 
Approved for issue on behalf of the IECEx
Certification Body:
D R Stubbings

 
Position:Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 09.0020X
 
Date of Issue:2010-07-13Issue No.: 5
 
Page 2 of 5
 
 Manufacturer:
ADS Environmental Services
4940 Research Drive
Huntsville
Alabama 35805
United States of America


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/SIR/ExTR09.0029/00GB/SIR/ExTR09.0101/00GB/SIR/ExTR09.0148/00GB/SIR/ExTR09.0204/01GB/SIR/ExTR10.0054/01GB/SIR/ExTR10.0158/00


Quality Assessment Report:

GB/SIR/QAR09.0012/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 09.0020X
 
Date of Issue:2010-07-13Issue No.: 5
 
Page 3 of 5
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The ADS Flowshark Triton (Model Number 8000-FST) or Flowhawk (Model Number 8000-FHK) Monitors are self-contained devices that measure/log depth and velocity in sewer pipes and open channels.  The Monitors use an enclosure that provides a degree of protection not less than IP20 and is made from a plastic cylinder, 28% Polypropylene GP220FA, 12% Fiberglass and 60% Polypropylene J440, with a metallic end cap, 6061-T6 aluminium, all thread forms are compatible with the alloy used.  There are three sockets for connection to sensors and a communication module, these sockets are arranged with either a different number of pins or are keyed so as to avoid the possibility of making a wrong interconnection.  The enclosure contains no terminals or compartments and is isolated from the internal circuits so that no connection facilities for earthing or bonding conductors are supplied.

   
The Monitor contains:an internal battery pack
 a regulator board
 a processor/analogue board
 interconnection cables between boards
 bulkhead sockets mounted on the processor/analogue board to provide connection to sensors
 It can also have either an IS GSM Modem (not part of this evaluation) or a Direct Connect Interface (part of this evaluation)
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

1.

Parts of the enclosure may be non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions.  The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam), which might cause a build-up of electrostatic charge on non-conducting surfaces.
2.As aluminium is used at the accessible surface of this equipment, in the event of rare incidents, ignition sources due to impact and friction sparks could occur.  This shall be considered when the Flowshark Triton/Flowhawk is being installed, particularly in locations that require equipment with a group II Ga level of protection.
3.The IS Modem DAA is only permitted to be connected to a “Public Switched Telephone Network”.
4.The ADS Model 8000-FHK/ 8000-FST shall only be used in the hazardous area when fully assembled, no maintenance of internal parts or battery changes shall be undertaken unless the unit is located in a safe area.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx SIR 09.0020X
 
Date of Issue:2010-07-13Issue No.: 5
 
Page 4 of 5
 
 
EQUIPMENT(continued):
 

In addition the communications connector “COMM” can have one of the following connected to it:

 
IS GSM Modem (not part of this evaluation)
Direct Connect Interface (part of this evaluation)
101624 Communications Interface
 
When the 101624 Communications Interface is used it provides external power.  In this case the internal battery pack is not fitted.
 
The sensors, designated as either Combo Sensor P/N 8K-CS1, P/N 8K-CS2 or P/N 8K-CS3, are externally connected to the Monitor and the sensor cable can be extended up to 300 ft (91 m).  They comprise a processor/signal conditioning board and piezoelectric transducers - these items are fully potted in either an ABS plastic enclosure, P/N 8K-CS1 and P/N 8K-CS2, or an aluminium enclosure, P/N 8K-CS3 (in this application, the construction of “CS1” and “CS2” are identical except for the frequency of operation of the crystals - one operates at 1 MHz and the other at 250 kHz).
 
The Direct Connect Interface is used to transfer data from either the Flowshark Triton or Flowhawk located in the hazardous area to a Personal Computer in the non-hazardous area.  It comprises a single PCB fully encapsulated inside a rectangular, plastic box with Emerson-Cummings type 2651MM epoxy resin.
 
The following types are marked on the relevant items of equipment:
 
Flowshark Triton (Model 8000-/FST)
Flowhawk (Model 8000-FHK)
Combo Sensor P/N 8K-CS1
Combo Sensor P/N 8K-CS2
Combo Sensor P/N 8K-CS3
Direct Connect Interface P/N 8000-0054
 
For input and output values, cabling and connections, refer to Certificate Annexe.
 
 
 