IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx NEM 09.0009 issue No.:2
 
Status:
Current
 
Date of Issue:2011-05-31 Page 1 of 4


    
Applicant:
Fluenta AS
Sandbrekkeveien 85
Po Box 115, Midtun
N-5828 BERGEN
Norway


 
Electrical Apparatus:Flare gas meter
Optional accessory:


 
Type of Protection:Ex de[ia] IIC T6, Ex ia IIC T6/T5/T4


 
Marking: Field Computer: Ex de[ia] IIC T6 Ta: -40°C to +60°C
Sensors: Ex ia IIC T6 Ta: -70°C to +60°C
Ex ia IIC T5 Ta: -70°C to +85°C
Ex ia IIC T4 Ta: -70°C to +120°C
 
Approved for issue on behalf of the IECEx
Certification Body:
Rolf Hoel

 
Position:Certification Manager, Ex products


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
NEMKO
Gaustadelleen 30
Oslo N-0314
Norway


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx NEM 09.0009
 
Date of Issue:2011-05-31Issue No.: 2
 
Page 2 of 4
 
 Manufacturer:
Fluenta AS
Sandbrekkeveien 85
Po Box 115, Midtun
N-5828 BERGEN
Norway


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-1 : 2003
Edition: 5
Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd'
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2004
Edition: 1
Electrical apparatus for explosve gas atmospheres - Part 26: Construction, test and marking of Group II Zone 0 electrical apparatus
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
NO/NEM/ExTR09.0003/00NO/NEM/ExTR09.0003/01NO/NEM/ExTR09.0003/02


Quality Assessment Report:

NO/NEM/QAR09.0001/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx NEM 09.0009
 
Date of Issue:2011-05-31Issue No.: 2
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Flare Gas Meter FGM 160

The Fluenta Flare Gas Meter FGM 160 is designed to measure the velocity of gases in a flare pipe. The Fluenta Flare Gas Meter consists of a Field Computer and Ultrasonic Sensors. The Field Computer is composed of an Increased safety “e” enclosure with terminal blocks and a Flameproof “d” enclosure containing the electronics. The output to the Ultrasonic sensors is supplied through IS-barriers (“ia”).
 
CONDITIONS OF CERTIFICATION: NO
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx NEM 09.0009
 
Date of Issue:2011-05-31Issue No.: 2
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Issue 1: New design of Flameproof enclosure (Ex d) and increased protection enclosure (Ex e).

Issue 2: Reference to Test Reports corrected

 
 