Certificate No.:
IECEx BAS 06.0011 issue No.:0
 
Status:
Current
 
Date of Issue:2006-03-17 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GB Limited
77 Ripponden Road
Oldham
Lancashire
OL1 4EL
United Kingdom


 
Equipment:Type KFD2-VR2-Ex1.50M Transformer Isolated Voltage Repeater
Optional accessory:


 
Type of Protection:Intrinsic Safety


 
Marking: IECEx BAS 06.0011
[Ex ia] IIC
[Ex ia] I
-20C ≤ Ta ≤ +60C
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:Managing Director


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa (2001) Ltd.
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 06.0011
 
Date of Issue:2006-03-17Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Konigsberger Allee 87
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE LTD
P + F Building
18 Ayer Rajah Crescent
39942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2000
Edition: 3.1
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 1999
Edition: 4
Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety 'i'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR06.0009/00


Quality Assessment Report:

DE/PTB/QAR06.0007/00DE/PTB/QAR06.0008/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 06.0011
 
Date of Issue:2006-03-17Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The Type KFD2-VR2-Ex1.50M Transformer Isolated Voltage Repeater is used to restrict the transfer of energy in the form of a low voltage analogue signal from unspecified non-hazardous area apparatus to intrinsically safe circuits located in a hazardous area. It also provides galvanic isolation between the hazardous area and non-hazardous area circuits.
The Type KFD2-VR2-Ex1.50M Transformer Isolated Voltage Repeater comprises a number of electrical components, including two isolating transformers, fuses, resistors and zener diodes all mounted onto a single printed circuit board (PCB) and housed within a plastic enclosure with plug-in terminals.

Input/output parameters

Non-hazardous Area Terminals 1 & 14 wrt 2 & 15 and 7 wrt 8

Um = 253V
The apparatus is designed to operate from a d.c. supply of up to 40V on the above terminals.


Hazardous Area Terminals 4 wrt 5

Uo=5.5V Co=58µF
Io=2.4mA Lo=1000mH
Po=3.3mW    

The capacitance and either the inductance or inductance to resistance ratio (L/R) of the load connected to output terminals of the apparatus must not exceed the following values:

Hazardous Area Terminals 4 wrt 5

GROUP
CAPACITANCE (µF)
INDUCTANCE  (mH)

OR
L/R RATIO (µH/ohm)

IIC
58
1000
  425
IIB
1000
1000
  425
IIA
1000
1000
  425
I
1000
1000
  425

Note: The above load parameters apply where:

1. The external circuit contains no combined lumped inductance Li and capacitance Ci greater than 1% of the above values.
Or
2. The inductance and capacitance are distributed as in a cable.
Or
3. The external circuit contains either only lumped inductance or lumped capacitance in combination with a cable.

In all other situations e.g. the external circuit contains combined lumped inductance or lumped capacitance, up to 50% of each of the L and C values is allowed.

 
CONDITIONS OF CERTIFICATION: NO
 
 