IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx PTB 05.0002X issue No.:0
 
Status:
Current
 
Date of Issue:2005-04-15 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
Electrical Apparatus:Temperature Multi Input Device, type **D0-TI-**
Optional accessory:


 
Type of Protection:"n"


 
Marking: Ex nA II T4
T amb -40°C up to +70°C
 
Approved for issue on behalf of the IECEx
Certification Body:
Dr.-Ing. Ulrich Johannsmeyer

 
Position:Head of Department "Intrinsic Safety and Safety of Systems"


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Physikalisch-Technische Bundesanstalt (PTB)
Bundesallee 100
38116 Braunschweig
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx PTB 05.0002X
 
Date of Issue:2005-04-15Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE Ltd.
P + F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-15 : 2001
Edition: 2
Electrical apparatus for explosive gas atmospheres - Part 15: Type of protection 'n'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
IECEx ATR:File Reference:
DE/PTB/05-002   B032238  
   
   


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx PTB 05.0002X
 
Date of Issue:2005-04-15Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The Temperature Multi Input Device, type **D0-TI-*** is used to measure analogue signals as well as for the bi-directional transfer of PROFIBUS or Foundation Fieldbus signals.
The Temperature Multi Input Device, type **D0-TI-*** is equipped with 8 analogue input circuits where resistance type sensors (e.g. RTDs, potentiomenters) and voltage sources (e.g. thermocouples, active voltage sources) can be connected.
Permissible ambient temperature range:             -40 °C up to +70 °C
Supply circuit                                          UN = 35 V
(terminals +, - )                                         maximum voltage Um = 253 V
Terminal “S”                                              for the connection of the cable shield (BUS)
                                                                  resp. the equipotential bonding only
Ground shield (at the housing)                  for the connection of the equipotential bonding only


Analogue input circuits                          the permissible maximum values are to be taken from
(terminals +, -; H, L)                                  the Certificate IECEx PTB 05.0001

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1.      The Temperature Multi Input Device, type **D0-TI-*** is to be installed in such a way that a degree of protection of at least IP54 according to IEC 60529 is achieved.
2.      The outside connectors of the supply circuit shall only be connected and disconnected when de-energized.
3.      The operation of switches and connecting and disconnecting of circuits under voltage, is only permitted during installation or for repair purposes.
 







Copyright © IEC-IECEx 2016 , Geneva Switzerland. All rights reserved.