IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx PTB 05.0001 issue No.:0
 
Status:
Current
 
Date of Issue:2005-04-15 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
Equipment:Temperature Multi Input Device, type **D0-TI-***
Optional accessory:


 
Type of Protection:General requirements, Intrinsic Safety


 
Marking: Ex ia IIC T4
resp.
[Ex ia] IIC
 
Approved for issue on behalf of the IECEx
Certification Body:
Dr.-Ing. U. Johannsmeyer

 
Position:Head of Department "Intrinsic Safety and Safety of Systems"


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Physikalisch-Technische Bundesanstalt (PTB)
Bundesallee 100
38116 Braunschweig
Germany, Physikalisch-Technische Bundesanstalt (PTB)
Bundesallee 100
38116 Braunschweig

Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx PTB 05.0001
 
Date of Issue:2005-04-15Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE Ltd.
P + F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2000
Edition: 3.1
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 1999
Edition: 4
Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety 'i'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
IECEx ATR:File Reference:
DE/PTB/05-001   B032237  
   
   


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx PTB 05.0001
 
Date of Issue:2005-04-15Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Temperature Multi Input Device, type **D0-TI-*** is used to measure analogue signals as well as for the bi-directional transfer of PROFIBUS or Foundation Fieldbus signals.

The Temperature Multi Input Device, type **D0-TI-*** is equipped with 8 analogue input circuits where resistance type sensors (e.g. RTDs, potentiomenters) or voltage sources (e.g. thermo- couple, active voltage sources) may be connected.

The Temperature Multi Input Device, type **D0-TI-*** may be operated as an intrinsically safe apparatus or as an associated intrinsically safe apparatus.

If used as an intrinsically safe apparatus inside the explosion hazardous area the Temperature Multi Input Device, type **D0-TI-*** is supplied by a certified intrinsically safe circuit (PROFIBUS PA or Foundation Fieldbus).

When operated as an associated intrinsically safe apparatus for the use outside the explosion hazardous area the Temperature Multi Input Device, type **D0-TI-*** is supplied by a non-intrinsically safe circuit (PROFIBUS PA or Foundation Fieldbus).

The intrinsically safe analogue input circuits are safely isolated from the supply circuit up to a peak value of 375 V of the nominal voltage.

 

 

Permissible ambient temperature range for both applications:

-40 °C up to +70 °C

 

 

Three versions of the Temperature Multi Input Device **D0-TI-*** are available:

 

Version 1:  Type RD0-TI-Ex*.****, consists only of the electronic part.

                   Type RD0-TI-Ex*.**** is required to be installed in any suitable

                   housing for this purpose.

 

Version 2:  Type F2D0-TI-Ex*.**** , consists of an enclosure (field housing

                   type F2***) and an electronic part RD0-TI-Ex*.****.

 

Version 3:  Type F6D0-TI-Ex*.**** , consists of an enclosure (stainless

                   steel*) and an electronic part RD0-TI-Ex*.***.

 

 

 

For electrical data reference is made to the annex IECExPTB0500010.pdf.

 
SPECIFIC CONDITIONS OF USE: NO
 
 







Copyright © IEC-IECEx 2016 , Geneva Switzerland. All rights reserved.