Date of Issue:2013-02-21Page 1 of 5
 
 
Applicant:
International Metal Engineering Pte Ltd
Blk 13
Toa Payoh Lorong 8
# 06-05 Braddell Tech Park
319261
Singapore
Equipment:7100, 8100, 8100Vx and 8100Px Series of Instrument Enclosures and Junction Boxes
 
Optional accessory:
 
Type of Protection:Flameproof and Dust

 Marking: Ex d IIC Gb
Ex tb Db IIIC
Ta = -40°C to +85°C
 
 
Approved for issue on behalf of the IECEx
Certification Body:
C Ellaby

 
Position:Deputy Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 08.0126U
 
Date of Issue:2013-02-21Issue No.: 3
 
Page 2 of 5
  
Manufacturer:
International Metal Engineering Pte Ltd
Blk 13
Toa Payoh Lorong 8
# 06-05 Braddell Tech Park
319261
Singapore


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-31 : 2008
Edition: 1
Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/SIR/ExTR09.0100/00GB/SIR/ExTR09.0138/00GB/SIR/ExTR13.0033/00


Quality Assessment Report:

GB/SIR/QAR07.0040/00GB/SIR/QAR07.0040/01GB/SIR/QAR07.0040/02GB/SIR/QAR07.0040/03


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 08.0126U
 
Date of Issue:2013-02-21Issue No.: 3
 
Page 3 of 5
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

Refer to EQUIPMENT (continued) for the product description



 SPECIFIC CONDITIONS OF USE:   NO
 
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 08.0126U
 
Date of Issue:2013-02-21Issue No.: 3
 
Page 4 of 5
 
 EQUIPMENT(continued):
 
 

8100Px

The 8100Px instrument enclosures and junction boxes are cylindrical single compartment enclosures comprising a base and cover with a maximum internal volume of 700 cm³. The enclosures are manufactured from cast aluminium with an epoxy paint finish. The enclosures cover may be solid aluminium or contain a circular tempered glass window. Each enclosure may have up to three conduit openings with entry sizes selected from ½” NPT, ¾” NPT, ½” BSP or M20x1.5.
7100 and 8100 Series
The 8100 and 7100 series instrument enclosures and junction boxes are cylindrical single compartment enclosures comprising a base and cover with a maximum internal volume of 950 cm³. The enclosures are manufactured from cast aluminium, with an epoxy paint finish, or stainless steel, the 7100 series are also available in cast aluminium. The enclosure covers may be solid aluminium/ stainless steel or contain a circular tempered glass window. A further option of a high cover with a window is available in stainless steel only. Each 7100 enclosure may have up to four conduit openings and each 8100 enclosure may have up to three conduit openings, with entry sizes selected from ½” NPT, ¾” NPT, 1” NPT, ½” BSP, M20 x 1.5 or M25 x 1.5.
8100Vx
The 8100Vx instrument enclosure is a cylindrical single compartment enclosure comprising a base and cover with a maximum internal volume of 950 cm³. The enclosures are manufactured from stainless steel. The enclosure covers may be solid stainless steel or contain a circular tempered glass window. Each enclosure may have up to six conduit openings, with entry sizes selected from ½” NPT or M20 x 1.5.
The enclosures meet the requirements of IP 68.
Refer to the Annexe for Design Options and Special Points for Noting
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 08.0126U
 
Date of Issue:2013-02-21Issue No.: 3
 
Page 5 of 5
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Issue 1 – this Issue introduced the following changes:

1The introduction of the 8100PB epoxy coated aluminium instrument enclosure with a blind cover to the range.
2The introduction of the 8100Vx stainless steel instrument enclosures with a blind or window cover.
3The descriptions have been amended accordingly.
Issue 2 – this Issue introduced the following change:
1Appropriate re-assessment to demonstrate compliance with the requirements of the latest editions of the IEC 60079 series of standards, the documents previously listed in the certificate IECEx SIR 08.0126U, IEC 60079-0:2007 Ed 5 and IEC 61241-1:2004 Ed 1, were replaced by those currently listed.
Issue 3 – this Issue introduced the following change:
1.The introduction of the 8100VL and 8100VT instrument enclosures to the 8100Vx product range. The new enclosures are manufactured from an alternative material to that originally certified. The design options for the additional enclosures are detailed in the annexe.
 
 