IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx SIR 10.0075X issue No.: 2
 
Status:
Current
 
Date of Issue:2018-03-06Page 1 of 4
 
 
Applicant:
International Metal Engineering PTE Limited
Blk 13
Toa Payoh Lorong 8
# 06-05 Braddell Tech Park
319261
Singapore
Equipment:5092 Range of Junction Boxes and 6092 Range of Instrument Enclosures
 
Optional accessory:
 
Type of Protection:Flameproof and Dust

 Marking:

Ex db IIC T6 Gb
Ex tb III C T85°C Db
Ta = -40°C to +70°C


 
 
Approved for issue on behalf of the IECEx
Certification Body:
C Ellaby

 
Position:Deputy Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
SIRA Certification Service
CSA Group
Unit 6, Hawarden Industrial Park
Hawarden, Deeside, CH5 3US
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 10.0075X
 
Date of Issue:2018-03-06Issue No.: 2
 
Page 2 of 4
  
Manufacturer:
International Metal Engineering PTE Limited
Blk 13
Toa Payoh Lorong 8
# 06-05 Braddell Tech Park
319261
Singapore


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2014-06
Edition: 7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/SIR/ExTR10.0173/00GB/SIR/ExTR12.0264/00GB/SIR/ExTR18.0013/00


Quality Assessment Report:

GB/SIR/QAR07.0040/01GB/SIR/QAR07.0040/02


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 10.0075X
 
Date of Issue:2018-03-06Issue No.: 2
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The 5092 and 6092 series are cylindrical single compartment enclosures with a maximum internal volume of 610 cm³.   They comprise a base and threaded cover, are manufactured from stainless steel or cast aluminium that and may have an epoxy paint coating. The cover can be blind or may contain a circular tempered glass window.   Each enclosure has a number of conduit openings and sizes. The enclosures are populated with either up to 2 PCBs or 10 x UK3N Phoenix Contact terminals. The maximum power dissipation within the enclosures is 7.5 W.  The enclosures meet the requirements of IP 66.  The part number breakdown and the product configurations are detailed in the certificate Annexe.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
  1. External thread types other than metric or NPT are not permitted as an option for cable glands in field wiring installations. Therefore, the user shall ensure that no such cable glands are installed in the enclosure entries.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx SIR 10.0075X
 
Date of Issue:2018-03-06Issue No.: 2
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

This issue, Issue 2, recognises the following change; refer to the certificate annex to view a comprehensive history:

 

  1. Following appropriate assessment to demonstrate compliance with the latest technical knowledge, IEC 60079-1:2007 Ed.6 and IEC 60079-31:2008 Ed.1 were replaced by IEC 60079-1:2014 Ed.7 and IEC 60079-31:2013 Ed.2, the markings and conditions were updated accordingly to recognise the new standards.
  2. Other external thread types (other than metric or NPT) are not permitted as an option for cable glands in field wiring installations in IEC 60079-1:2014 Annex C.2.2, therefore a specific condition of use is added to this certificate. A “suffix X” is therefore applied to the certificate.
 
 