IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 08.0088X issue No.:5
 
Status:
Current
 
Date of Issue:2012-06-01 Page 1 of 4


    
Applicant:
Thermocoax Isopad GmbH
Englerstrasse 11
Heidelberg D-69126
Germany


 
Electrical Apparatus:Drum and gas bottle heaters types FIDR-SR, FIBDR-SR and FIGB-SR
Optional accessory:


 
Type of Protection:Flameproof, Increased safety, Intrinsically safe, Encapsulation, Electrical resistance trace heating, Dust protected


 
Marking: For marking, see schedule
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0088X
 
Date of Issue:2012-06-01Issue No.: 5
 
Page 2 of 4
 
 Manufacturer:
Thermocoax Isopad GmbH
Englerstrasse 11
Heidelberg D-69126
Germany


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-1 : 2003
Edition: 5
Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd'
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-18 : 2004
Edition: 2.0
Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation 'm' electrical apparatus
IEC 60079-30-1 : 2007-01
Edition: 1
Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements
IEC 60079-7 : 2001
Edition: 3
Electrical apparatus for explosive gas atmospheres - Part 7: Increased safety 'e'
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
IEC 61241-18 : 2004
Edition: 1.0
Electrical apparatus for use in the pressence of combustible dust - Part 18: Protection by encapsulation "mD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR08.0190/00GB/BAS/ExTR09.0154/00GB/BAS/ExTR10.0090/00GB/BAS/ExTR10.0162/00GB/BAS/ExTR12.0137/00


Quality Assessment Report:

GB/BAS/QAR09.0003/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0088X
 
Date of Issue:2012-06-01Issue No.: 5
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The drum and gas bottle heaters types FIDR and FIGB comprise a tubular stainless steel jacket to which is attached self regulating heating cables, either a manual or an electronic thermostat, terminals boxes and thermal insulation. The steel jacket is split into two halves to enable it to enclose the drum or gas bottle. The type FIBDR is a circular or disc jacket for placing under a drum. A non heated drum cover may be provided.

Marking

The FIDR, FIGB heater assemblies are marked:-
Ex d e IIC T2             Ex tD A21 IP6X T240°C   or
Ex d e IIC T4         Ex tD A21 IP6X T130°C or
Ex d e IIC T6         Ex tD A21 IP6X T80°C
Tamb =  -40°C to +50°C

The FIBDR heater assemblies are marked:-

Ex e ia m IIC T2    Ex tD A21 IP6X T240°C or
Ex e ia m IIC T4    Ex tD A21 IP6X T130°C
or
Ex e ia m IIC T6    Ex tD A21 IP6X T80°C
Tamb =  -40°C to +50°C

 

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1.  The supply circuit must include an electrical protection device in conformity with Clause 4.4 of IEC62086-1.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 08.0088X
 
Date of Issue:2012-06-01Issue No.: 5
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Variation 5.5

This issue permits existing information (for example on Schedule Drawings) to be replaced by the revised certificate holders name. No other changes may be made to the certified design
 
 








Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.