IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 10.0025X issue No.:1
 
Status:
Current
 
Date of Issue:2012-03-01 Page 1 of 4


    
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Electrical Apparatus:Resistance Repeater Type KCD2-RR-Ex1
Optional accessory:


 
Type of Protection:Type n


 
Marking: Ex nA II T4 Gc
(-20°C≤ Ta ≤ +60°C)
 
Approved for issue on behalf of the IECEx
Certification Body:
R. S. Sinclair

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0025X
 
Date of Issue:2012-03-01Issue No.: 1
 
Page 2 of 4
 
 Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
PT. Pepperl + Fuchs
Bintan
SD 56, 57 Lobam, Bintan Industrial Estate
IND-Pulau Bintan
Riau
Indonesia
Pepperl + Fuchs (Manufacturing) PTE LTD
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-15 : 2010
Edition: 4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR10.0050/00GB/BAS/ExTR12.0043/00


Quality Assessment Report:

DE/PTB/QAR06.0007/02DE/PTB/QAR06.0008/03


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0025X
 
Date of Issue:2012-03-01Issue No.: 1
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Resistance Repeater Type KCD2-RR-Ex1 is designed to transfer a resistance value from a hazardous area to unspecified apparatus located in a non-hazardous area. The hazardous area circuit is galvanically isolated from the non-hazardous area circuit using transformers and the voltage and current appearing at the hazardous area connection pins is limited to intrinsically safe levels.

The Resistance Repeater Type KCD2-RR-Ex1 comprises a number of electronic components including three isolating transformers, fuses, zener diodes and resistors all mounted on a single printed circuit board and housed in a plastic enclosure with removable terminals. An LED provides power status indication.

This certificate covers the installation of the Resistance Repeater Type KCD2-RR-Ex1 (IECEx BAS 10.0024) in a Category 3 / Zone 2 location.

See Annex for electrical data.

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

1.  The Resistance Repeater Type KCD2-RR-Ex1 must be installed in a suitably certified enclosure such that it is afforded a degree of protection of at least IP54 in accordance with IEC 60529 and IEC 60079-15.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0025X
 
Date of Issue:2012-03-01Issue No.: 1
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Variation 1.1

To permit the use of Phoenix spring terminal plugs as an alternative to the screw terminal plug. Units fitted with the spring terminal plugs will have the addition of “.SP” to the type name i.e. KCD2-RR-Ex1.SP.

Variation 1.2

To confirm that the equipment covered by this certificate has been reviewed against the requirements of IEC 60079-0:2007 and IEC 60079-15:2010 in respect of the differences from IEC 60079-0:2004 and IEC 60079-15:2005 and that none of these differences affect this equipment; the equipment is now marked as follows:

Ex nA II T4 Gc  (-20°C ≤ Ta ≤ +60°C)

 ExTR:  GB/BAS/ExTR12.0043/00

File Reference:   11/0857

 
 
 








Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.