IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx CSA 09.0010X issue No.:4
 
Status:
Current
 
Date of Issue:2014-12-29 Page 1 of 4


    
Applicant:
Watlow Missouri Inc - dba Watlow Hannibal
6 Industrial Loop Road
Hannibal, MO
USA
63401
United States of America


 
Equipment:Flange Immersion Heaters, Series F*
Optional accessory:


 
Type of Protection:Ex d


 
Marking:

Ex d IIC T1-T6 Gb 

-60 C < Tamb < + 80 C

 
Approved for issue on behalf of the IECEx
Certification Body:
Dorin Stochitoiu

 
Position:Technical Advisor


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
CSA International
178 Rexdale Boulevard
Toronto, Ontario M9W IR3
Canada
and
1707 - 94th Street
Edmonton, AB T6N 1E6
Canada


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx CSA 09.0010X
 
Date of Issue:2014-12-29Issue No.: 4
 
Page 2 of 4
 
 Manufacturer:
Watlow Missouri - dba Watlow Hannibal
6 Industrial Loop Road
Hannibal, MO
USA
63401
United States of America


 
 Additional Manufacturing location(s):
Watlow Electric Manufacturing (Shanghai) Co. Ltd
Building 5 , No 358 Shenxia Road Forward High Tech Zone,
Jia Ding Dist,
Shanghai
201818
China

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
CA/CSA/ExTR09.0016/00CA/CSA/ExTR09.0016/01CA/CSA/ExTR09.0016/02CA/CSA/ExTR09.0016/03CA/CSA/ExTR09.0016/04


Quality Assessment Report:

DE/TUR/QAR10.0001/01DE/TUR/QAR14.0003/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx CSA 09.0010X
 
Date of Issue:2014-12-29Issue No.: 4
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Flange Immersion Heaters Series F.  Rated 690 Vac max, 1 or 3 phase, 120 W/sq. in max tubular.  Ambient temperature range: - 60 deg C to + 80 deg C.

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 

The settings of the temperature control devices of the heater bundle shall be such that the surface temperature does not exceed its stated temperature class. 

The gap between the body and the cover shall not exceeed 0.038 mm. 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx CSA 09.0010X
 
Date of Issue:2014-12-29Issue No.: 4
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Variation 1

a) Addition of three nominal heating element diameter options : 4.480" (12.19 mm), 0.685" (17.40 mm) and 0.935"(23.75mm). b) Increased maximum heater sheath watt density to 120watts/square inch. c) Updates to Manufacturer's Documents to include additional elelment diamter options and watt density, as wellas minor paperwork changes. Special conditions of safe use appear on the certiifcate.

Variation 2

a) Increased maximum upper ambient temperature to 60 deg C (from 40 degC). b) Updates to Manufacturer's Documents to include ambient temperature range up to 60 deg C.

Variation 3

a) Increased maximum upper ambient temperature to 80 deg C (from 60 deg C). b) Expanded gas group to Group IIC (from Group IIB + H2). c) Expnaded rated voltage to 690 Vac (from 600 Vac). d) Changed Series designation to Series F ( from Series FX). e) Updates to Manufacturer's Documents to include changes.

Variation 4

a) Decreased lower ambient temperature to -60 degC( from -40 deg C).b) Updated Manufacturer's Documents to include temperature and minor paperwork changes. c) Add alternate manufacturing location.

 

 
 