Certificate No.:
IECEx DNV 09.0001X issue No.:0
 
Status:
Current
 
Date of Issue:2009-11-30 Page 1 of 3


    
Applicant:
Purge Solutions
12450 Galveston Road, Suite C, Webster
Texas 77598, USA
United States of America


 
Equipment:Purge controllers and purge indicators
Optional accessory:


 
Type of Protection:Ex e, mb, p ib, nL, nA, tD


 
Marking: See annex
 
Approved for issue on behalf of the IECEx
Certification Body:
Marianne Spæren

 
Position:Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DNV
Det Norske Veritas (DNV) Certification AS
Veritasveien 1
1322 Hovik
Norway


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx DNV 09.0001X
 
Date of Issue:2009-11-30Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Purge Solutions
12450 Galveston Road, Suite C, Webster
Texas 77598, USA
United States of America


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2005-03
Edition: 3
Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking of Type of Protection "n" electrical apparatus
IEC 60079-18 : 2004
Edition: 2.0
Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation 'm' electrical apparatus
IEC 60079-2 : 2001
Edition: 4
Electrical apparatus for explosive gas atmospheres - Part 2: Pressurized enclosures 'p'
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
NO/DNV/ExTR09.0007/00


Quality Assessment Report:

NO/DNV/QAR09.0002/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx DNV 09.0001X
 
Date of Issue:2009-11-30Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

See annex

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 

-        When these purge indicators/controllers are used with a pressurised enclosure the pneumatic parameters

       and overall temperature class must be defined in a separate certificate.

-          When the purge controllers are mounted in the enclosure wall of the pressurised enclosure, this

       enclosure must be at least IP54 in order to comply with the requirements to Ex-e.

-          The CYCLOPS Y version must be supplied from an intrinsically safe barrier for the power input and the

       alarm output.

 

 