IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx INE 09.0022X issue No.:0
 
Status:
Current
 
Date of Issue:2009-11-09 Page 1 of 4


    
Applicant:
Masoneilan D.P.I.
3, rue Saint Pierre BP 87
F-14110 Condé sur Noireau
France


 
Electrical Apparatus:DIGITAL LEVEL TRANSMITTER AND CONTROLLER Type 12400
Optional accessory:


 
Type of Protection:ia, iaD and nL


 
Marking: Ex ia IIC T6, T5 or T4
Ex iaD 20 IP66/67 T85°C, T100°C or T135°C
Ex nL IIC T6, T5 or T4
 
Approved for issue on behalf of the IECEx
Certification Body:
Thierry Houeix

 
Position:Ex Certification Officer


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
INERIS
Institut National de l'Environnement Industriel
et des Risques
BP n2
Parc Technologique ALATA
F-60550 Verneuil-En-Halatte
France


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx INE 09.0022X
 
Date of Issue:2009-11-09Issue No.: 0
 
Page 2 of 4
 
 Manufacturer:
Masoneilan D.P.I.
3, rue Saint Pierre BP 87
F-14110 Condé sur Noireau
France


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2005-03
Edition: 3
Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking of Type of Protection "n" electrical apparatus
IEC 60079-26 : 2004
Edition: 1
Electrical apparatus for explosve gas atmospheres - Part 26: Construction, test and marking of Group II Zone 0 electrical apparatus
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-11 : 2005
Edition: 1
Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'iD'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
FR/INE/ExTR09.0024/00


Quality Assessment Report:

FR/LCI/QAR08.0006/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx INE 09.0022X
 
Date of Issue:2009-11-09Issue No.: 0
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

This digital level transmitter and controller is constituted by an electrical and mechanical compartment. The electrical compartment is protected by intrinsic safety.

These two compartments get the international protection IP66/67 according to the standard IEC 60529.

 

 

 

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

When the materials compositions of the enclosure is in aluminium, the user will have to read the instructions.

 

The other conditions are stipulated in the instructions.

 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx INE 09.0022X
 
Date of Issue:2009-11-09Issue No.: 0
 
Page 4 of 4
 
 
Additional information:
 
ROUTINE EXAMINATIONS AND TESTS

None.

 

PARAMETERS RELATING TO THE SAFETY
Maximum input characteristics to the following terminals:

 

AO1

Ui (V)

Ii (mA)

Pi (mW)

Ci (nF)

Li (µH)

30

125

900

2

500

 

 

AO2

Ui (V)

Ii (mA)

Pi (mW)

Ci (nF)

Li (µH)

30

125

900

9.0

500

 

 

DO1

Ui (V)

Ii (mA)

Pi (mW)

Ci (nF)

Li (µH)

30

125

900

4.5

10

 

 

DO2

Ui (V)

Ii (mA)

Pi (mW)

Ci (nF)

Li (µH)

30

125

900

4.5

10

 

MARKING

MASONEILAN D.P.I

F - 14110 Condé sur Noireau

12400

IECEx INE 09.0022X

(Serial number)

Ex ia IIC T(*)

Ex nL IIC T(*)

Ex iaD 20 IP66/67 T(**)

Tamb : (***)

WARNING: POTENTIAL DANGER OF ELECTROSTATICS CHARGES - SEE INSTRUCTIONS

 

Ambient temperature range – Tamb.***

Temperature class

Gas *

Dust **

-40°C / 55°C

T6

T85°C

-40°C / 70°C

T5

T100°C

-40°C / 80°C

T4

T135°C

 

 

 

 
 