| IECEx Certificate
of Conformity |
|
 | |  |  |  |
 | Schedule |
 | |  |  |  |
 | EQUIPMENT: |  |  |  |
 | Equipment and systems covered by this certificate are as follows: |
 | |
 | The devices are Ex e II terminal enclosures constructed out of brushed finish 316L stainless steel and are available in various sizes and depths. The enclosures consist of a cover, hinge assembly, body, external and internal grounding lugs, gland plates, gaskets and welded mounting lugs. The enclosure may be mounted in a vertical or horizontal position. |
Enclosure Catalog Numbers Covered by the Certificate: VC4X6 followed by 0906XXY-Z, 1208XXY-Z, 1212XXY-Z, 1612XXY-Z, 1616XXY-Z, 1620XXY-Z, 2016XXY-Z, 2024XXY-Z. VH4X6 followed by 2626XX, 3030XX, 3826XX, 4538XX, 4848XX, 5035XX, may be followed by A, B C or D which designates the location of the gland plate. Nomenclature: |
VC4X6 0906 | 05 | H | A | I | II | III | IV |
| I. Basic Enclosure Designation | | II. Depth of Enclosure | | Replace with any two-digit number (16 max) | | III. Mounting Feet | | H - Horizontal | | V - Vertical | | IV. Gland Plate Location | | A - Gland Plate on Top Side | | B - Gland Plate on Bottom Side | | C - Gland Plate on Left Side | | D - Gland Plate on Right Side |
| I. Basic Enclosure Designation | | II. Depth of Enclosure | | Replace with any two-digit number (41 max) | | III. Gland Plate Location | | A - Gland Plate on Top Side | | B - Gland Plate on Bottom Side | | C - Gland Plate on Left Side | | D - Gland Plate on Right Side |
|
|
 | |  |  |  |
 | CONDITIONS OF CERTIFICATION: YES as shown below: |
 | |  |  |  |
 | - The number of conductors entering an enclosure plus the number of internal connections (bridges and ground conductors are not counted) shall not exceed that of the Enclosure Size Terminal content Sheets. All terminals shall be evaluated according to IEC 60079-7:2006 and covered by a Component Certificate for the actual use, current and voltage.
- After installation, all creepage distances and clearances shall be according to Table 1 in IEC 60079-7:2006, 4th Edition.
|
|
 | |  |  |  |
 |  |  |  |  |
 |  |  |  |  |
 |  |  |  |  |