Certificate No.:
IECEx FTZU 08.0004X issue No.:2
 
Status:
Current
 
Date of Issue:2012-01-31 Page 1 of 4


    
Applicant:
Emerson Process Management GmbH & Co. OHG
Industriestrasse 1
D-63594 Hasselroth
Germany


 
Electrical Apparatus:Flameproof Gas Analyzer X-STREAM X2FD and X-STREAM XEFD
Optional accessory:


 
Type of Protection:Flameproof enclosure


 
Marking: II 2G Ex d IIB + H2 T4 Gb
 
Approved for issue on behalf of the IECEx
Certification Body:
Jaroslav Šindler dipl. ing.

 
Position:Head of certification body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Fyzikalne technicky zkusebni ustav
(Physical -Technical Testing Institute)
Pikartska 7
71607 Ostrava - Radvanice
Czech Republic


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FTZU 08.0004X
 
Date of Issue:2012-01-31Issue No.: 2
 
Page 2 of 4
 
 Manufacturer:
Emerson Process Management GmbH & Co. OHG
Industriestrasse 1
D-63594 Hasselroth
Germany


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
CZ/FTZU/ExTR08.0004/00CZ/FTZU/ExTR08.0004/01CZ/FTZU/ExTR08.0004/02


Quality Assessment Report:

DE/TUR/QAR08.0001/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FTZU 08.0004X
 
Date of Issue:2012-01-31Issue No.: 2
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

X-STREAM series gas analyzers are intended to be used as analyzers for industrial purposes. Analyzer types X-STREAM X2FD and X-STREAM XEFD is designed with flameproof enclosure and consists of enclosure body and cover with sight glass. The body and cover are made of Al alloy and fastened by bolts. There are six threaded inserts in the enclosure cover providing passage of control rods.  The enclosure has four threaded holes for cable glands or plugs and eight threaded holes for flame arresters or their closing devices.

The instruction manual see documents No. HASXMDE-IM-EX 01/2012 and HASXEDE-IM-EX 01/2012. 

 

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

Special conditions for safe use (includind dimensions of flameproof gaps) are specified at the chapter 1.5.1 of the Instruction Manuals of the manufacturer No. HASXMDE-IM-EX 01/2012 and HASXEDE-IM-EX 01/2012

Appropriate certified cable glands shall be used in accordance with IEC 60079-14.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FTZU 08.0004X
 
Date of Issue:2012-01-31Issue No.: 2
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Extension of new variant – vapour recovery application. This application is served by a special configuration of the X-STREAM X2FD and X-STREAM XEFD flameproof analyzer. The configuration consists of a dual channel IR measurement, connected to the inlet and outlet of a converter. This converter is installed inside the X-STREAM analyzer and is heated to about 280°C. This application is used for simultaneous measurement of CH4 and non-CH4.
Technical parameters:
Ambient temperature -30°C to +50°C
Power supply 100-240V AC; 50/60 Hz; 3-1,5A
 
 
 








Copyright © IEC-IECEx 2014 , Geneva Switzerland. All rights reserved.