Certificate No.:
IECEx CSA 14.0014X issue No.: 0

Certificate history:

 
Status:
Current
 
Date of Issue:2015-03-26Page 1 of 3
 
 
Applicant:
Exlar Industrial Actuators
Curtiss-Wright
18400 West 77th Street, Chanhassen, MN 55317
United States of America
Equipment:EL120 (linear) and ER120 (rotary) actuators
 
Optional accessory:
 
Type of Protection:Ex d

 Marking:

Ex d IIB+H2 T4 Gb

Ta: -29C to +93C

 
 
Approved for issue on behalf of the IECEx
Certification Body:
Dorin Stochitoiu

 
Position:Technical Advisor


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
CSA Group
178 Rexdale Boulevard
Toronto, Ontario M9W IR3
Canada


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx CSA 14.0014X
 
Date of Issue:2015-03-26Issue No.: 0
 
Page 2 of 3
  
Manufacturer:
Exlar Industrial Actuators
Curtiss-Wright
18400 West 77th Street, Chanhassen, MN 55317
United States of America


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

CA/CSA/ExTR15.0003/00


Quality Assessment Report:

CA/CSA/QAR09.0021/03


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx CSA 14.0014X
 
Date of Issue:2015-03-26Issue No.: 0
 
Page 3 of 3
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The EL120 (linear) and ER120 (rotary) series actuators are IP66, brushless, servo motor powered electro-mechanical, bi-directional actuators which comprise of four main parts as follows:

End Cap Housing, containing the electrical components, Case (motor housing), Face Plate and End Plate.

These four main parts are manufactured from aluminium whilst the linear and rotary shafts comprise of stainless steel or steel.

Both the EL120 and ER120 have a Manual Drive Shaft option, in this configuration, the Manual Drive Shaft Housing is fastened between the End Cap Housing and Case (motor housing) of the actuator.

The Manual Drive Shaft Housing is manufactured from aluminium and the Hand Crank Shaft material is stainless steel.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
Specific Conditions of Use (ER120)

 

i.        At the cable entry point the surface temperature may reach up to 105°C, therefore, supply cable and entries shall be selected accordingly

 

ii.       The maximum voltage and current ratings marked on the equipment shall not be exceeded.

 

iii.      Due to the requirements of clause 5.1 of EN 60079-1:2007, it shall be pointed out that the joint dimensions of the flameproof enclosure deviate from the values in tabulated in EN 60079-1. Any maintenance of the critical dimensions of the flamepaths shall not be undertaken without seeking guidance from the manufacturer of the equipment.

 

iv.      Special Fasteners Yield Strength:

 

(4X) Tie Rod

(4X) Tie Rod Washer(4X)  Tie Rod Nut

800 Mpa

500 MPa

700 MPa

   

(8X) Face Plate

(4X) Manual Drive Shaft Housing

(8X) Attach Plate

700 MPa

695 MPa

700 MPa

 

Specific Conditions of Use (EL120) 

 

v.       At the cable entry point the surface temperature may reach up to 105°C, therefore, supply cable and entries shall be selected accordingly

 

vi.      The maximum voltage and current ratings marked on the equipment shall not be exceeded.

 

vii.   Due to the requirements of clause 5.1 of EN 60079-1:2007, it shall be pointed out that the joint dimensions of the flameproof enclosure deviate from the values tabulated in EN 60079-1.  The only component that is allowed to be maintained is the removal of the gland assembly for re-greasing as defined in the User Manual.  As this is the only joint allowed for maintenance the joint dimensions are detailed as follows:

       

Joint

Design Gap MaximumDesign Length (min)
Gland Assembly/Face Plate0.033 mm30.0 mm
 

viii.    Special Fasteners Yield Strength:

 

(4X) Tie Rod

(4X) Tie Rod Washer(4X) Tie Rod Nut
800 Mpa500 MPa700 MPa
   

(8X) Gland Assembly

(4X) Manual Drive Shaft Housing

695 MPa

695 MPa

 

Note: The only maintenance component allowed is the removal of the gland assembly for re-greasing as defined in User Manual hence see item vii.

 

 




Copyright © IEC-IECEx 2018 , Geneva Switzerland. All rights reserved.