IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx UL 08.0012X issue No.:0
 
Status:
Current
 
Date of Issue:2009-06-12 Page 1 of 3


    
Applicant:
Adalet, A Scott Fetzer Co.
4801 W. 150th Street
Cleveland, OH 44135
United States of America


 
Electrical Apparatus:Terminal Enclosures
Optional accessory:


 
Type of Protection:Increased Safety "e" and Dust "tD"


 
Marking: Ex e II T5/T6
Ex tD A21 IP66 T200C
 
Approved for issue on behalf of the IECEx
Certification Body:
Paul T. Kelly

 
Position:Lead Operations Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Underwriters Laboratories Inc (UL)
333 Pfingsten Road
Northbrook IL 60062-2096
United States of America


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx UL 08.0012X
 
Date of Issue:2009-06-12Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Adalet, A Scott Fetzer Co.
4801 W. 150th Street
Cleveland, OH 44135
United States of America


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
US/UL/ExTR08.0014/00


Quality Assessment Report:

US/UL/QAR08.0003/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx UL 08.0012X
 
Date of Issue:2009-06-12Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The devices are Ex e II terminal enclosures constructed out of brushed finish 316L stainless steel and are available in various sizes and depths.  The enclosures consist of a cover, hinge assembly, body, external and internal grounding lugs, gland plates, gaskets and welded mounting lugs.  The enclosure may be mounted in a vertical or horizontal position.

 

Enclosure Catalog Numbers Covered by the Certificate: 

 

VC4X6 followed by 0906XXY-Z, 1208XXY-Z, 1212XXY-Z, 1612XXY-Z, 1616XXY-Z, 1620XXY-Z, 2016XXY-Z, 2024XXY-Z.

 

VH4X6 followed by 2626XX, 3030XX, 3826XX, 4538XX, 4848XX, 5035XX, may be followed by A, B C or D which designates the location of the gland plate.

 

Nomenclature:  

 

VC4X6 0906 

05 

A 

II 

III 

IV 

 

I.        Basic Enclosure Designation 
II.       Depth of Enclosure 
                Replace with any two-digit number (16 max)
III.      Mounting Feet  
                H - Horizontal
                V - Vertical
IV.      Gland Plate Location 
                A - Gland Plate on Top Side  
                B - Gland Plate on Bottom Side
                C - Gland Plate on Left Side
                D - Gland Plate on Right Side

 

VH4X6 2626 

16 

A 

II 

III 

 

I.        Basic Enclosure Designation 
II.       Depth of Enclosure
                Replace with any two-digit number (41 max)
III.      Gland Plate Location 
                A - Gland Plate on Top Side
                B - Gland Plate on Bottom Side
                C - Gland Plate on Left Side
                D - Gland Plate on Right Side

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
  • The number of conductors entering an enclosure plus the number of internal connections (bridges and ground conductors are not counted) shall not exceed that of the Enclosure Size Terminal content Sheets.  All terminals shall be evaluated according to IEC 60079-7:2006 and covered by a Component Certificate for the actual use, current and voltage.
  • After installation, all creepage distances and clearances shall be according to Table 1 in IEC 60079-7:2006, 4th Edition.
 







Copyright © IEC-IECEx 2014 , Geneva Switzerland. All rights reserved.