Certificate No.:
IECEx BAS 07.0047 issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2007-10-11 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
Equipment:Type KFD2-HLC-Ex1.D.** HART Loop Converter
Optional accessory:


 
Type of Protection:Intrinsic Safety


 
Marking: IECEx BAS 07.0047
[Ex ia] IIC
[Ex iaD]
-20°C ≤ Ta ≤ +60°C
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:Managing Director


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa (2001) Ltd.
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom, SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton, Derbyshire, SK17 9RZ

United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 07.0047
 
Date of Issue:2007-10-11Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE Ltd
P + F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-11 : 2005
Edition: 1
Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'iD'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR07.0092/00


Quality Assessment Report:

DE/PTB/QAR06.0007/01DE/PTB/QAR06.0008/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 07.0047
 
Date of Issue:2007-10-11Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Type KFD2-HLC-Ex1.D.** HART Loop Converter is designed to transfer up to three dynamic variables from a HART field device located in the hazardous area to unspecified apparatus located in the non-hazardous area using the HART protocol. The voltage and current passed to the hazardous area is limited to intrinsically safe levels. The hazardous area circuit is galvanically isolated from the non-hazardous area circuit using transformers.  

The Type KFD2-HLC-Ex1.D.** HART Loop Converter comprises a number of electronic components, including isolating transformers, fuses, zener diodes and resistors mounted on two inter-connected printed circuit boards and housed in a plastic enclosure with polarised plug-in terminals for hazardous and non-hazardous area connections. A Liquid Crystal Display (LCD) with push buttons is provided on the front of the enclosure to allow the user to monitor and configure the operation of the apparatus in addition to LED indication for Power-on and channel status. A jack socket is provided for updating the apparatus firmware using the data terminal.

There are three models of the Type KFD2-HLC-Ex1.D.** HART Loop Converter, the Type KFD2-HLC-Ex1.D providing the basic functions and the Type KFD2-HLC-Ex1.D.2W HART Loop Converter with two output relays and the Type KFD2-HLC-Ex1.D.4S HART Loop Converter with four output relays. The models fitted with relays provide either two or four relay outputs to the non-hazardous area for fault indication. All models in terms of intrinsic safety are identical.

See annex for electrical parameters

 
SPECIFIC CONDITIONS OF USE: NO
 
 