IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 09.0115 issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2010-03-11 Page 1 of 3


    
Applicant:
The Linde Group
The Priestley Centre
10 Priestley Road
Guildford
GU2 7XY
United Kingdom


 
Equipment:G-TECTA SG Flammable Gas Detector
Optional accessory:


 
Type of Protection:Intrinsic Safety, Flameproof


 
Marking: IECEx BAS 09.0115
Ex ia d IIC T4 Gb (-20C ≤ Ta ≤ +65C)
 
Approved for issue on behalf of the IECEx
Certification Body:
R.S. Sinclair

 
Position:Managing Director


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 09.0115
 
Date of Issue:2010-03-11Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
The Linde Group
The Priestley Centre
10 Priestley Road
Guildford
GU2 7XY
United Kingdom


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR09.0181/00


Quality Assessment Report:

GB/BAS/QAR10.0002/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 09.0115
 
Date of Issue:2010-03-11Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The G-TECTA SG Flammable Gas Detector is designed to detect the presence of flammable gas, give a visual indication of the concentration, and give audible and visual alarms if a preset level is exceeded. It comprises a rechargeable battery, a flammable gas sensor head, electronic circuits on printed circuit boards, a liquid crystal display, LED’s and a piezo sounder, all contained in a plastic enclosure providing a degree of protection of at least IP20. External contacts are provided for recharging, and for serial data communications.

The flammable gas sensor module fitted is known as a flammable i-module. The flammable i-module can be replace in the apparatus with an oxygen i-module (for oxygen deficiency detection), or a toxic i-module. The permitted i-modules are listed in the User Manual provided by the manufacturer.The apparatus is not designed for use in oxygen enriched atmospheres.

Charging conditions:

The apparatus can be recharged or connected to serial communications when in a non-hazardous area, using the G-TECTA SG Desktop Charger / Interface Part Number ASSG1059 or G-TECTA SG Desktop Charger Part Number ASSG1058. Alternatively, any Linde charger with an output (Um) of 9V may be used to charge the apparatus, although when both charging and data communications are required, only charger / interface part number ASSG1059 must be used.
 
SPECIFIC CONDITIONS OF USE: NO
 
 