IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 09.0118 issue No.:0
 
Status:
Current
 
Date of Issue:2010-03-11 Page 1 of 3


    
Applicant:
The Linde Group
The Priestley Centre
10 Priestley Road
Guildford
GU2 7XY
United Kingdom


 
Equipment:G-Tecta 4GP
Optional accessory:


 
Type of Protection:ia d


 
Marking: IECEx BAS 09.0118
Ex ia d IIC T4 Gb (-20 °C ≤ Ta ≤ +55 °C )
or
Ex ia d IIC T3 Gb (-20 °C ≤ Ta ≤ +55 °C )
 
Approved for issue on behalf of the IECEx
Certification Body:

 
Position:


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 09.0118
 
Date of Issue:2010-03-11Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
The Linde Group
The Priestley Centre
10 Priestley Road
Guildford
GU2 7XY
United Kingdom


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2003
Edition: 5
Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd'
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR09.0236/00


Quality Assessment Report:

GB/BAS/QAR10.0002/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 09.0118
 
Date of Issue:2010-03-11Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The G-TECTA 4GP Gas Detector is designed to monitor the concentration of oxygen (deficiency), toxic or flammable gas, and provide visual, audible and physical (vibrator) warnings if preset limits are exceeded.
The presence of any sensor is optional and the maximum possible is one flammable, one oxygen and two toxic.

It comprises electronic circuits on printed circuit boards, a display, various LED indicators, a pump, a vibrator, a sounder and a rechargeable lithium-ion battery, all contained in a plastic enclosure providing a degree of protection of at least IP20.
The flammable sensor used is either type VQ500 series by E2V Technologies, to Certificate IECEx SIR04.0014U, or 4P series by City Technology to Certificate IECEx SIR04.0013U, with a Code of Ex d IIC Gb and a maximum permitted ambient temperature of +55ºC. These sensors are certified to IEC60079-0:2007 and IEC60079-1: 2007.
The IR Sensor used is type MSH-P Series by Dynament to Certificate IECEx SIR05.0053U, with a Code of Ex d IIC Gb and a maximum permitted ambient temperature of +60ºC.   This sensor is certified to IEC60079-0:2004, IEC60079-1:2003 and IEC60079-26:2006.

Marking of the Gas Detector is in accordance with IEC 60079-0:2007 and is:
Ex ia d IIC T4 Gb (-20ºC ≤ Ta ≤ +55ºC).

The apparatus is not designed for use in oxygen enriched atmospheres.

Charging conditions:The battery must only be recharged in a non-hazardous area, using a Linde charger with an output (Um) of 9V.

Non-rechargeable instrument:

There is a non-rechargeable version of the instrument which has Temperature Class T3 and is therefore marked:
Ex ia d IIC T3 Gb (-20ºC ≤ Ta ≤ +55ºC).

The batteries must only be changed in a non-hazardous area.

 
SPECIFIC CONDITIONS OF USE: NO
 
 