IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx KDB 14.0001X issue No.: 1
 
Status:
Current
 
Date of Issue:2016-11-30Page 1 of 5
 
 
Applicant:
APLISENS S.A.
ul. Morelowa 7, 03-192 Warszawa
Poland
Equipment:Smart Pressure Transmitter type APC-2000ALW/XX, APC-2000ALW/XX Ex Safety, Smart Differential Pressure Transmitter type APR-2000ALW/XX, APR-2200ALW/XX, APR-2000ALW/XX Ex Safety, APR-2000GALW/XX, APR-2000GALW/XX Ex Safety, Smart Level Probe type APR-2000YALW/XX
 
Optional accessory:
 
Type of Protection:Flameproof enclosure "d", Dust protection by enclosure "t", Intrinsic safety "i"

 Marking: version with steel enclosure:  
   Ex db ia I Mb, Ex ia/db IIC T6/T5 Ga/Gb, Ex ia/t III C T85°C/T100°C Da/Db
or 
   Ex db ia I Mb, Ex ia/db IIC T6/T5 Gb, Ex ia/t III C T85°C/T100°C Db

version with aluminium alloy enclosure:

   Ex ia/db IIC T6/T5 Ga/Gb, Ex ia/t III C T85°C/T100°C Da/Db,

or

   Ex ia/db IIC T6/T5 Gb, Ex ia/t III C T85°C/T100°C Db

 
 
Approved for issue on behalf of the IECEx
Certification Body:
mgr inż. Ksawery Graboś

 
Position:Head of ExCB


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
Główny Instytut Górnictwa, Kopalnia Doświadczalna "BARBARA"
(Central Mining Institute Experimental Mine "Barbara")
ul. Podleska 72
43-190 Mikołów
Poland


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx KDB 14.0001X
 
Date of Issue:2016-11-30Issue No.: 1
 
Page 2 of 5
  
Manufacturer:
APLISENS S.A.
ul. Morelowa 7, 03-192 Warszawa
Poland


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2014-06
Edition: 7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

PL/KDB/ExTR14.0001/00PL/KDB/ExTR14.0001/01


Quality Assessment Report:

PL/KDB/QAR12.0001/00PL/KDB/QAR12.0001/01PL/KDB/QAR12.0001/02


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx KDB 14.0001X
 
Date of Issue:2016-11-30Issue No.: 1
 
Page 3 of 5
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 
Pressure transmitters type APC-2000ALW/XX, APC-2000ALW/XX Ex Safety and differential pressure transmitters type APR-2000ALW/XX, APR-2200ALW/XX, APR-2000ALW/XX Ex Safety, APR-2000GALW/XX, APR-2000GALW/XX Ex Safety and level probes type APR-2000Y/ALW/XX work by converting proportional to the measured pressure resistance changes of piezoresistive bridge, located in the single crystal of silicon diaphragm, into a standard current signal 4 ÷ 20 mA with HART communications signal.The basic units of the transmitter and probe is a measuring head (Ex i) with a silicon diaphragm sensor. Measuring head can be equipped with different pressure connections. Inside the head there is the "pressure chamber" filled with manometer liquid. On the side of measured medium it is limited by a diaphragm welded tightly to the head’s body (differential pressure transmitters have two separated diaphragms for the inputs: "+" and "-"). The measuring head is mounted in the housing and secured with two screws.In the heads to measure differential pressure and absolute pressure the tight bushings are applied. For overpressure measurements at a pressure range head to 7MPa, bushings are used with the opening from which a tube connecting the rear side of the measuring diaphragm to the atmosphere is pulled out; there are cylindrical flameproof joints used additionally in this case and in some versions of pressure difference heads. The transmitters with the head versions described above have EPL Ga/Gb and Da/Db.

 



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
- Only those elements can be used as replacing ones which are specified in the descriptive documentation;

- Some of the permitted gaps in the flameproof joints are smaller and the lengths of the flameproof joints are greater than the ones specified in table 1 IEC 60079-1. The relevant information for the user is included in the manual;

- In areas where there is a risk of dust explosion, transmitters in aluminium alloy casing covered with lacquer and transmitters with plastic rating plates or with diaphragm seals covered by Teflon should be installed in a way to prevent electrostatic charging according to the operation manual.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx KDB 14.0001X
 
Date of Issue:2016-11-30Issue No.: 1
 
Page 4 of 5
 
 EQUIPMENT(continued):
 
 

In the versions pressure transmitters APC... and differential pressure transmitters APR... of EPL Gb and Db (measured in zone 1 or 21) all pressure heads are allowed, including those without additional flame-proof joints.Enclosures of transmitters are made of die-cast aluminium alloy or stainless steel. Enclosure consists of a body and two screwed covers (display and electrical connection). The cable line is introduced the enclosure flameproof cable gland with thread M20x1,5 or 1/2NPT depending on the version of the housing body. In the non-used opening the explosion-proof plug (cap) prod. APLISENS S.A is mounted.The transmitters may be fitted with diaphragm seals, which enable them to be used in a variety of conditions such as thick or highly reactive media, high and low temperatures. Elements of the diaphragm seals can be coated with Teflon.

In the name of transmitters types the letters "XX" stand for the symbol of process connection used.

Technical parameters:

 

Range of the measured pressure:

-100kPa ÷ 100MPa (APC-2000ALW, APC-2000ALW Ex Safety)

-160kPa ÷ 7MPa   (APR–2000ALW, APR–2200ALW, APR-2000ALW Ex Safety)

-10 kPa ÷ 10 kPa (APR-2000GALW, APR-2000GALW Ex Safety)


Range of the measured liquid level:

0 ÷ 10mH2O (APR–2000YALW)

Output signal:

4÷20mA in a two-wire system + HART

Supply voltage:

10,5V ÷ 55V - standard version1

10,5V ÷ 45V - MID version

16V ÷ 45V- safety version

Ingress protection:

IP66 / IP67

Ambient temperature:

–40 ÷ 45°C/75°C (depending on the temperature class)

–50°C ÷ 45°C/75°C (special version)

–25 ÷ 55°C (MID version) 

 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx KDB 14.0001X
 
Date of Issue:2016-11-30Issue No.: 1
 
Page 5 of 5
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

There is a modification in the construction of the pressure transmitters type APC-2000ALW/XX, differential pressure transmitters type APR-2000ALW/XX, APR-2200ALW/XX, and level probes type APR-2000YALW/XX. Pressure transmitters and differential pressure transmitters of EPL Gb and Db have been introduced. The new performances of the pressure transmitters and differential pressure transmitters APC-2000ALW/XX Ex Safety, APR-2000ALW/XX Ex Safety, APR-2000GALW/XX, APR-2000GALW/XX Ex Safety have been introduced. The changes in the parameters of power supply to 55V and a minimum temperature of -50°C (transmitters in special version) have been introduced.

 
 




Copyright © IEC-IECEx 2018 , Geneva Switzerland. All rights reserved.