IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx FTZU 09.0001 issue No.: 1
 
Status:
Current
 
Date of Issue:2012-03-14Page 1 of 4
 
 
Applicant:
APLISENS S.A.
Morelowa 7,
03-192 Warszawa
Poland
Equipment:Pressure and differential pressure transmitters PC-28/xx/yy, PCE-28/xx/yy, PC-28P/xx/yy, PCE-28P/xx/yy, PR-28/xx/yy, PRE-28/xx/yy
 
Optional accessory:
 
Type of Protection:Intrinsic safety

 Marking: Ex ia IIC T4...T6, Ga/Gb
Ex ia I Ma
 
 
Approved for issue on behalf of the IECEx
Certification Body:
Dipl. Ing. Lukáš Martinák

 
Position:Head of certification body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
Fyzikalne technicky zkusebni ustav
(Physical -Technical Testing Institute)
Pikartska 7
71607 Ostrava - Radvanice
Czech Republic


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx FTZU 09.0001
 
Date of Issue:2012-03-14Issue No.: 1
 
Page 2 of 4
  
Manufacturer:
APLISENS S.A.
Morelowa 7,
03-192 Warszawa
Poland


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

CZ/FTZU/ExTR09.0001/00


Quality Assessment Report:

PL/KDB/QAR12.0001/00


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx FTZU 09.0001
 
Date of Issue:2012-03-14Issue No.: 1
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

Pressure transmitters PC-28, PCE-28 are designed to measure positive gauge pressure, vacuum pressure and absolute pressure of gases, vapors and liquids.The transmitters PC-28P, PCE-28P are designed to measure of level of liquid.Differential pressure transmitters PR-28, PRE-28 are designed to measure liquid levels in closed tanks and to measure differential pressure across constructions. The electronic part is identical in all versions.The active sensing element is a silicon diaphragm with in-diffused piezoresistors located in a sensing module.The electronic part amplifies and standardizes the signal from measuring bridge to the output signal 4 to 20 mA.The electronic circuitry except of filter board is encapsulated in a stainless steel enclosure.The external circuit connection facility differs according to the model as follows:

  •  PD (angular connector produced by Hirschmann)
  •  PZ (terminal box with cable gland PG-11)
  •  PK (permanently connected cable). The letters xx indicate type of process connector, yy indicate the type of electric connector.

The transmitters intended for use as group II equipment are allowed to be installed into the partition between the hazardous areas zone 0 and zone 1. 
Technical parameters: Ui = 28 V DC; Ii = 0.1 A; (for linear power supply characteristic), Ii = 0,08 A (for rectangular or trapezial power supply characteristic).  Pi = …see the table in attachment , L= 0.9 mH; Ci = 40 nF

Ambient temperature:   Ta …see the attachement

Instruction for use - see document DTR.PC.PR-28



 SPECIFIC CONDITIONS OF USE:   NO
 
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx FTZU 09.0001
 
Date of Issue:2012-03-14Issue No.: 1
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 
Change of QAR number - new certified body applied
 
 