IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BVS 09.0033 issue No.:2
 
Status:
Current
 
Date of Issue:2011-09-22 Page 1 of 6


    
Applicant:
Cooper Crouse-Hinds GmbH
Neuer Weg-Nord 49,
69412 Eberbach
Germany


 
Electrical Apparatus:Fluorescent lighting fixture type eLL* ** ***/** *
Optional accessory:


 
Type of Protection:flameproof enclosures "d", increased safety "e", protection by enclosures "tD"


 
Marking: Ex de IIC T4 for type ZB and without option
Ex de mb ib IIC T4 for type NIB and CG-S
Ex tD A21 IP66 T80°C for all types
 
Approved for issue on behalf of the IECEx
Certification Body:
Dr. F. Eickhoff

 
Position:Deputy Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0033
 
Date of Issue:2011-09-22Issue No.: 2
 
Page 2 of 6
 
 Manufacturer:
Cooper Crouse-Hinds GmbH
Neuer Weg-Nord 49,
69412 Eberbach
Germany


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/BVS/ExTR09.0031/02


Quality Assessment Report:

DE/BVS/QAR11.0009/00


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0033
 
Date of Issue:2011-09-22Issue No.: 2
 
Page 3 of 6
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
General product information (for issue 1 to 2):
The fluorescent lighting fixture type eLL* ** ***/** * is an explosion-protected electrical apparatus that accommodates single or twin fluorescent luminaires with either lamp cap FA6 (one-pin) or lamp cap G13 (bi-pin).
 
Only separately certified EVGs, either one single, one double or two singles, are used as electronic ballast.
 
The luminaires may be replaced inside the potentially explosive atmosphere if the fluorescent lighting fixture is equipped with a separately evaluated light switch which disconnects the light at all poles or if the voltage of the lighting fixture is set to zero before changing the luminaire. The variant without a light switch contains a relevant warning on the outside of the enclosure.
 
The lighting fixtures that are equipped with a luminaire size T12 (38mm diameter) are exclusively used with mechanical protection.
 
The enclosure of the fixture consists of either glass-mat reinforced polyester or of stainless steel; the light-permitting diffuser is made of polycarbonate.
 
A separately certified battery box with an as component certified battery can be assembled to one of the front ends of the lighting fixture for emergency use.
 
A separately certified CG-S module can be assembled inside the lighting fixture for monitoring functions.
 
Type Code (for issue 1 to 2):
Without change
 
CONDITIONS OF CERTIFICATION: NO
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0033
 
Date of Issue:2011-09-22Issue No.: 2
 
Page 4 of 6
 
 
EQUIPMENT(continued):
 
Thermal data (for issue 1 to 2)
Ambient temperature range if U < 220V -25°C ≤ Ta ≤ +50°C
Ambient temperature range if U ≥ 220V -25°C ≤ Ta ≤ +55°C
 
 
Electrical data (for issue 1 to 2):
 
One-pin lamp cap type FA6
Type of luminaireType of electronic ballastNominal voltageFrequency
eLL* ** 318/18 1x EVG 05 218 respectively
1x EVG 09 218
110V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 318/181x EVG 05 217 respectively
1x EVG 09 217
110V - 254V AC
110V - 127V DC
50Hz - 60Hz
eLL* ** 336/361x EVG 05 236 respectively
1x EVG 09 236
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 336 1x EVG 05 136 respectively
1x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 336/362x EVG 05 136 respectively
2x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 358/58 1x EVG 05 258 respectively
1x EVG 09 258
220V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 358 1x EVG 05 158 respectively
1x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 358/582x EVG 05 158 respectively
2x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 336/36 ZB 2x EVG 05 136 respectively
2x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 358/58 ZB2x EVG 05 158 respectively
2x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 318/18 NIB1x VE/EVG 05 218220V - 254V AC
110V - 127V AC
50Hz - 60Hz
eLL* ** 336 NIB1x VE 97 236 +
1x EVG 05 136 respectively
1x EVG 09 136
220V - 254V AC
110V - 127V AC
50Hz - 60Hz
eLL* ** 336/36 NIB1x VE 97 236 +
1x EVG 05 236 respectively
1x EVG 09 236
220V - 254V AC
110V - 127V AC
50Hz - 60Hz
 
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0033
 
Date of Issue:2011-09-22Issue No.: 2
 
Page 5 of 6
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

The reason of the supplement is the change of the used QAR.
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0033
 
Date of Issue:2011-09-22Issue No.: 2
 
Page 6 of 6
 
 
Additional information:
 
Bi-pin lamp cap type G13
Type of luminaireType of electronic ballastNominal voltageFrequency
eLL* ** 018/181x EVG 05 218 respectively
1x EVG 09 218
110V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 018/181x EVG 05 217 respectively
1x EVG 09 217
110V - 254V AC
110V - 127V DC
50Hz - 60Hz
eLL* ** 036/361x EVG 05 236 respectively
1x EVG 09 236
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 0361x EVG 05 136 respectively
1x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 036/362x EVG 05 136 respectively
2x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 058/58 1x EVG 05 258 respectively
1x EVG 09 258
220V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 0581x EVG 05 158 respectively
1x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 058/582x EVG 05 158 respectively
2x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 036/36 ZB2x EVG 05 136 respectively
2x EVG 09 136
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 058/58 ZB 2x EVG 05 158 respectively
2x EVG 09 158
110V - 254V AC
110V - 250V DC
50Hz - 60Hz
eLL* ** 018/18 NIB 1x VE/EVG 05 218220V - 254V AC
110V - 127V AC
50Hz - 60Hz
eLL* ** 036/36 NIB 1x VE 97 236 +
1x EVG 05 236 respectively
1x EVG 09 236
220V - 254V AC
110V - 127V AC
50Hz - 60Hz
eLL* ** 36 NIB 1x VE 97 236 +
1x EVG 05 136 respectively
1x EVG 09 136
220V - 254V AC
110V - 127V AC
50Hz - 60Hz
eLL* ** 018/18 CG-S 1x EVG 05 218 respectively
1x EVG 09 218
+CG-S Modul
220V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 036/36 CG-S 1x EVG 05 236 respectively
1x EVG 09 236
+CG-S Modul
220V - 254V AC
195V - 250V DC
50Hz - 60Hz
eLL* ** 058/58 CG-S 1x EVG 05 258 respectively
1x EVG 09 258
+CG-S Modul
220V - 254V AC
195V - 250V DC
50Hz - 60Hz
 
 








Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.