Certificate No.:
IECEx ETL 11.0003 issue No.:0
 
Status:
Current
 
Date of Issue:2011-11-03 Page 1 of 3


    
Applicant:
Environment One Corporation
2773 Balltown Road
Niskayuna, New York 12309
United States of America


 
Electrical Apparatus:Dual Hydrogen Control Panel (DHCP)
Optional accessory:


 
Type of Protection:d [ia] ia [ib] ib nA


 
Marking: Ex d [ia] ia [ib] ib nA IIB + H2 T4 Gc
 
Approved for issue on behalf of the IECEx
Certification Body:
Donald Card

 
Position:Certification Officer


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Intertek
165 Main Street
Cortland NY 13045-2995
United States of America


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx ETL 11.0003
 
Date of Issue:2011-11-03Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Environment One Corporation
2773 Balltown Road
Niskayuna, New York 12309
United States of America


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2010
Edition: 4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
US/ETL/ExTR11.0003/00


Quality Assessment Report:

GB/ITS/QAR08.0008/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx ETL 11.0003
 
Date of Issue:2011-11-03Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Next Generation DHCP (Dual Hydrogen Control Panel) is designed for use with hydrogen-cooled generators and is intended for use in Zone 2, Group IIB +H2 hazardous locations.

 

The equipment is intended to be placed in a fixed location and permanently connected to a single electrical supply source (mains). The DHCP may also be equipped with an optional panel mounted GCM-X (Generator Condition Monitor).

 

 
CONDITIONS OF CERTIFICATION: NO
 
 