IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx TUR 11.0006X issue No.:0
 
Status:
Current
 
Date of Issue:2011-05-25 Page 1 of 3


    
Applicant:
R. Stahl HMI Systems GmbH
Im Gewerbegebiet Pesch 14
D- 50 767 Köln
Germany


 
Electrical Apparatus:Operator Interface ET-**6-A-*-***
Optional accessory:


 
Type of Protection:d, e, i, iD, m, op is, t


 
Marking: Ex d e ia ib mb [ia ib] IIC T4 Gb and
Ex ia tb [ia ib] IIIC T80°C Db IP66 for type code TX
Ex d e ia ib mb [ia ib op is] IIC T4 Gb and
Ex ia tb [ia ib op is] IIIC T80°C Db IP66 for type code FX
see attachment and manual for alternative marking
 
Approved for issue on behalf of the IECEx
Certification Body:
Dipl.-Ing. Heinz Farke

 
Position:Depity of ExCB


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
TUV Rheinland Industrie Service GmbH
Am Grauen Stein
51105 Cologne
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUR 11.0006X
 
Date of Issue:2011-05-25Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
R. Stahl HMI Systems GmbH
Im Gewerbegebiet Pesch 14
D- 50 767 Köln
Germany


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-18 : 2009
Edition: 3
Explosive atmospheres Part 18: Equipment protection by encapsulation "m"
IEC 60079-28 : 2006-08
Edition: 1
Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
IEC 60079-31 : 2008
Edition: 1
Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-11 : 2005
Edition: 1
Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'iD'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/TUR/ExTR11.0006/00


Quality Assessment Report:

DE/BVS/QAR10.0002/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUR 11.0006X
 
Date of Issue:2011-05-25Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The Exicom ET-**6-A-*-*** devices are operator interfaces or panel PCs for installation in hazardous locations classified for zones 1, 2, 21 and 22.The entire devices are built in housings that are protected against liquids and dust without need to be installed in hazardous locations certified cabinets.The different models vary in display size (10" to 15") and overall size, front panel with or without keyboard and overall functionality. Three main functionalities are (characterized by the first type code number): ET-3*6-A-*-***:      STAHL operating system for user application;ET-4*6-A-*-***:       Standard operation system (e.g. Windows Embedded, Linux etc.) ET-5*6-A-*-***:      Windows Embedded Standard operating system for remote applications. 

Internal construction of all devices is equal for most parts for all models.

All models have several interfaces to connect external devices as keyboards, joysticks, trackballs, RFID- or barcode-scanner etc.Communication with PLC networks and automation systems is achieved by different interfaces (RS-232, RS-485, Ethernet fiber optic or copper wire Ethernet links) connected in the "Ex-e"-area at the back of the devices.

Assembling of accessory as USB memory sticks and hard disk drives is previewed

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
For  ET - * * 6 - A - * - *SR* :The front of the operator interface equipped with a sunlight readable display
(type code includes “SR”) may be cleaned with a damp cloth only.

 

 







Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.