IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx LCI 10.0003X issue No.:0
 
Status:
Current
 
Date of Issue:2010-02-10 Page 1 of 3


    
Applicant:
ITALVIBRAS G. SILINGARDI SpA
Via Puglia 2/4
41049 Sassuolo (MODENA)
Italy


 
Electrical Apparatus:Electric Vibrators
Optional accessory:


 
Type of Protection:e, tD


 
Marking: ITALVIBRAS G.SILINGARDI s.p.a
Address : …
Type : …
Serial number : …
Year of construction : …
Ex e II T3, T4 or T…°C*
Ex tD A21 IP6X T120°C
Un : ...V In : ....A P : ....W
Ia/In : … tE : …s
WARNING : DO NOT OPEN WHEN ENERGIZED
TEMPARATURE OF CABLE GLAND : 105°C for T4, 180°C for T3, 120°C for T120°C
* according to manufacturer’s technical construction file.
 
Approved for issue on behalf of the IECEx
Certification Body:

 
Position:


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Laboratoire Central des Industries Electriques (LCIE)
33 Avenue du General Leclerc
FR-92260 Fontenay-aux-Roses
France


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx LCI 10.0003X
 
Date of Issue:2010-02-10Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
ITALVIBRAS G. SILINGARDI SpA
Via Puglia 2/4
41049 Sassuolo (MODENA)
Italy


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
FR/LCI/ExTR08.0018/00FR/LCI/ExTR08.0018/01


Quality Assessment Report:

IT/CES/QAR08.0003/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx LCI 10.0003X
 
Date of Issue:2010-02-10Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Asynchronous electric motor with centrifugal counter weight (eccentric weights) on both ends of the motor shaft, to produce oscillating vibrations on a machine.

Model/type reference covered by this certificate of conformity :

MVSI...-S90, IM...-S90, VM...-S90, VMS...-S90, UR...-S90, MVSI...-S02, IM...-S02, VM...-S02, VMS...-S02, UR...-S02, MTF...-S90, MTF...-S02, VB..., MVB..., MVB-FLC... 

 

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

- The cable clamping shall be made near the cable entry.

-All accessories associated to the vibrator motor to ensure smooth operation and safety must provide a recognized protection type, adapted to their specific use.

 







Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.