IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx CQM 10.0008 issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2010-03-01 Page 1 of 3


    
Applicant:
Cooper Electronic Technologies (Shanghai) Co., Ltd.
No 955, Sheng Li Road, Heqing, Pu Dong, Shanghai City
Postal Code: 201201
China


 
Electrical Apparatus:Explosion-protected Flourescent Fixture Type cLLK07...
Optional accessory:


 
Type of Protection:Ex "d", Ex "e", Ex "ib", Ex "q", Ex "tD'


 
Marking: cLLK07... type:
Ex deq IIC T4
Ex tD A21 IP66 T80 ℃
Ta:-20 ℃ ~ +50 ℃
cLLK07...N type:
Ex deibq IIC T4
Ex tD A21 IP66 T80 ℃
Ta:-20 ℃ ~ +40 ℃
 
Approved for issue on behalf of the IECEx
Certification Body:
Zhang Wei

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
China Quality Mark Certification Group Co., Ltd.
No. 33 Zengguang Road, Haidian District,
Beijing City, Postal code: 100037
China


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx CQM 10.0008
 
Date of Issue:2010-03-01Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Cooper Electronic Technologies (Shanghai) Co., Ltd.
No 955, Sheng Li Road, Heqing, Pu Dong, Shanghai City
Postal Code: 201201
China


 
 Additional Manufacturing location(s):
Cooper Electrical Australia Pty Ltd.
205-209 Woodpark Road, Smithfield
NSW 2164
Australia
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-5 : 2007-03
Edition: 3
Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
CN/CQM/ExTR10.0010/00


Quality Assessment Report:

AU/TSA/QAR06.0020/03GB/BAS/QAR07.0041/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx CQM 10.0008
 
Date of Issue:2010-03-01Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Description of equipment

 

The fluorescent lighting fixture type cllk series consists of the housing, reflector kits which is fixed by screws and locking bars, as well as the protection cover with seal and locking mechanism.

This fluorescent lighting fixture is suitable for use in hazardous location classified as Zone 1, Zone 2, Zone 21 and Zone 22. The input wire is fed in via separately certified cable glands. Unused entries are sealed with certified plugs to maintain the degree of protection.

The fluorescent lighting fixture is equipped with a separately certified lighting switch which disconnects the lighting at all poles when the enclosure of the fluorescent lighting fixture is opened.

 

 

Rating

 

For cLLK07…type: Non-emergency lighting

Rated voltage: AC220V ~ 240V 50Hz/60Hz, DC220V

Rated power: 2 x 18W, 2 x 36W

Ta:-20 ℃ ~ +50 ℃

For cLLK07…N type: Emergency lighting

Rated voltage: AC220V ~ 240V 50Hz/60Hz

Rated power: 2 x 18W, 2 x 36W

Ta:-20 ℃ ~ +40 ℃

 

 

 
CONDITIONS OF CERTIFICATION: NO
 
 







Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.