IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 10.0051X issue No.:6
 
Status:
Current
 
Date of Issue:2012-04-16 Page 1 of 4


    
Applicant:
Dialight Europe Ltd
Exning Road
Newmarket
Suffolk
CB8 0AX
United Kingdom


 
Electrical Apparatus:WPA Series LED Luminaire
Optional accessory:


 
Type of Protection:Encapsulation, flameproof, increased safety, protection by enclosure


 
Marking: Ex d e mb IIC T6 Gb
Ex tb IIIC T85°C Db IP66/67
Ta -40°C to+50°C
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
Baseefa
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0051X
 
Date of Issue:2012-04-16Issue No.: 6
 
Page 2 of 4
 
 Manufacturer:
Dialight Europe Ltd
Exning Road
Newmarket
Suffolk
CB8 0AX
United Kingdom


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-18 : 2009
Edition: 3
Explosive atmospheres Part 18: Equipment protection by encapsulation "m"
IEC 60079-31 : 2008
Edition: 1
Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
GB/BAS/ExTR10.0084/00GB/BAS/ExTR10.0154/00GB/BAS/ExTR10.0262/00GB/BAS/ExTR11.0102/00GB/BAS/ExTR11.0306/00GB/BAS/ExTR12.0101/00


Quality Assessment Report:

GB/BAS/QAR10.0009/01


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0051X
 
Date of Issue:2012-04-16Issue No.: 6
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The Type WPA Series LED Luminaire consists of a rectangular cast aluminium enclosure with a glass cover held in aluminium frame which is secured to the enclosure using 4 screws. Adequate sealing to maintain the IP66/67 ingress protection rating is ensured by a silicone O-ring and a silicone gasket between the glass and the frame.

The enclosure contains an Ex d electronic driver circuit covered by certificate IECEx BAS10.0046X or IECEx BAS10.0047X and a component LED Module covered by IECEx BAS10.0050U. The LED Modules include up to 27 LEDs of which 18 may be powered up at any one time.

The luminaire is rated for connection to a 100-277V ac supply.

Variation 0.1

To allow use at an increased ambient temperature of +60°C in which case the marking becomes:

Ex d e mb IIC T5 Gb      Ex tb IIIC T100°C Db IP66/67    Ta -40°C to +60°C

Variation 0.2

To allow the luminaire to be mounted recessed in which case the ambient temperature is reduced by 5°C and the marking becomes:

Ex d e mb IIC T6 Gb      Ex tb IIIC T85°C Db IP66/67    Ta -40°C to +45°C
Or
Ex d e mb IIC T5 Gb      Ex tb IIIC T100°C Db IP66/67    Ta -40°C to +55°C

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1. Suitably certified cable entries must be used which include a sealing washer to maintain the IP66/67 rating of the enclosure.

2. The supply to the luminaire must include a fuse which is capable of interrupting a 1500A short circuit current.   

3. The 24-48V DC luminaire must only be used with a galvanically isolated circuit

4.The transportable luminaire must be de-energised before being moved and must not be used if it is dropped or damaged during transportation.

5. When the plastic lens is fitted the luminaire must not be located in a dust laden air-stream.

 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BAS 10.0051X
 
Date of Issue:2012-04-16Issue No.: 6
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Variation 6.1

To allow a transportable option where the bulkhead luminaire is mounted onto a frame allowing it to be moved and used at temporary worksites.

Variation 6.2

To allow an optional external frame to support a plastic lens in front of the glass cover.

Variation 6.3

To allow an alternative LED tray to be used incorporating 5 x 0.5W LEDs. In this configuration the luminaire is suitable for an ambient temperature range  of -40°C < Ta < +40°C for T6 or -40°C < Ta < +50°C for T5. The upper ambient temperatures are reduced by 5°C for recess mount luminaires.

Variation 6.4

Minor internal changes including some component changes.

Variation 6.5

Minor label changes including an optional re-designation of the products as SafeSite WPA Series LED Luminaires.

Variation 6.6

Addition of Conditions of Certification Nos. 4 and 5.

 

 ExTR:  GB/BAS/ExTR12.0101/00

File Reference:   12/0185
 
 
 








Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.