IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx ITA 11.0026X issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2012-01-10 Page 1 of 3


    
Applicant:
Joy Mining Machinery
177 Thorn Hill Rd,
Warrendale,
PA
15086
United States of America


 
Electrical Apparatus:Switch Enclosure Type 5100006014
Optional accessory:


 
Type of Protection:Flameproof


 
Marking: Ex d I
 
Approved for issue on behalf of the IECEx
Certification Body:
Ian Hunter

 
Position:Certification Authority


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
TUV Rheinland Australia Pty. Ltd
4 - 6 Second Street
Bowden SA 5007
Australia


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx ITA 11.0026X
 
Date of Issue:2012-01-10Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Joy Mining Machinery
177 Thorn Hill Rd,
Warrendale,
PA
15086
United States of America


 
 Additional Manufacturing location(s):

These products may be
manufactured at any Joy
Mining Facility listed on IECEx
QAR GB/SIR/QAR07.0007/02
and its supplements, that have
been successfully audited for
the manufacturer of Type of
Protection Ex d.
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
AU/ITA/ExTR12.0004/00


Quality Assessment Report:

GB/SIR/QAR07.0007/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx ITA 11.0026X
 
Date of Issue:2012-01-10Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
The switch enclosure is manufactured from steel.  No welding is used on the enclosure except to secure the M6 plug on the side of the enclosure, which forms a separate flameproof threaded joint.  The flameproof enclosure is approximately 144mm wide x 206mm long x 82mm high.  It has a spindle protruding from the side for actuating the internal switch and a threaded entry (M36 x 1.5 x 6H) on the opposite side of the spindle and on the opposite top end of the enclosure.  The threaded entry on the opposite end is used for the nut and elastomeric seal of the straight gland construction certified in IECEx TSA 06.0030U to form an integral gland.

The cover is secured with six recessed M10 x 1.25 x 25mm socket head cap screws.

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
Conditions of certification / manufacture:  
  • It is a condition of certification that a copy of drawing 5100006014, Instructions and a copy of the Certificate must be provided with each enclosure.
  • The integral gland cable requirements, including size and torque requirements as per IECEx TSA 06.0030U approval, must be made available to the end user.
Special conditions of use: 
  • Only a suitably certified gland or blanking plug may be used in the threaded side entry.
  • The integral gland cable requirements, including size and torque requirements must be met as supplied by the manufacturer. 
  • Some flamepaths are in excess of the minimum design allowances of the standard and must be considered during maintenance / repair, using the information supplied by the Manufacturer.
  • The enclosure is machine mounted and the mounting shall be such as to ensure proper electrical connectivity to the machine, such that the enclosure is electrically bonded to the machine.
 







Copyright © IEC-IECEx 2013 , Geneva Switzerland. All rights reserved.