Certificate No.:
IECEx TUN 04.0001 issue No.:1
 
Status:
Current
 
Date of Issue:2007-09-10 Page 1 of 4


    
Applicant:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
Equipment:Solenoid driver module
Optional accessory:type: KFD2-SL2-Ex* and KFD2-SL2-Ex*.B


 
Type of Protection:Intrinsic safety


 
Marking: [Ex ia] IIC
[Ex iaD]
 
Approved for issue on behalf of the IECEx
Certification Body:
Karl-Heinz Schwedt

 
Position:Head of the IECExCB


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
TÜV NORD CERT GmbH & Co. KG
Am TUV1
D-30519 Hannover
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUN 04.0001
 
Date of Issue:2007-09-10Issue No.: 1
 
Page 2 of 4
 
 Manufacturer:
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs GmbH
Königsberger Allee 87
68307 Mannheim
Germany
Pepperl + Fuchs PTE Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-11 : 2005
Edition: 1
Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'iD'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
IECEx ATR:File Reference:
DE/TUN/ExTR07.0013/00   07203553933-1 to -4  
   
   


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUN 04.0001
 
Date of Issue:2007-09-10Issue No.: 1
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

The solenoid driver module type KFD2-SL2-Ex* resp. KFD2-SL2-Ex*.B is used as associated apparatus for the driving of valves. The solenoid driver module is built as 1-channel or 2-channel type. Errors just as open-circuiting or short-line fault are transformed to the power rail and do not exist at the version KFD2-SL2-Ex*.B.

 

The maximum permissible ambient temperature range is -20°C to +50°C for the 2-channel type

but -20°C to +60°C for the 1-channel type.

 

Electrical data

 

Supply circuit(terminals 14 and 15resp. PR1 and PR2) 

Direct voltage                      U = 20 V – 30 V

Maximum voltage                 U m = 40 V

Signal circuit error-output(PR4 and PR2)

For connection to a signal circuit only

Maximum voltage                   U m = 40 V 

Input circuits(terminals 7 and 8 and/or9 and 8) 

Direct voltage                         U = 16 V – 30 V

Maximum voltage                    U m = 60 V

Output circuits(terminals 1 and 2, 3 and/or4 and 5, 6) 

in type of protection “Intrinsic Safety”          

 Ex ia IIC / IIB / IIA   resp.  Ex ib IIC / IIB / IIA   resp. Ex iaD

Maximum values per circuit:

U o = 28 V

I o = 110 mA

P o = 770 mW

 

The effective internal capacitance and inductance are negligibly small.

The maximum permissible values for the external capacitance and inductance are given in the following table:

 Ex ia/ib IICEx ia/ib IIBEx ia/ib IIA
C o83 nF650 nF2,15 µF
L o3 mH12 mH23 mH

 

The table shown above applies for:

 

Distributed inductance and capacitance e.g. as in cables

or

for circuits containing up to 1% inductance or 1% capacitance in combination with a cable

or

for combined inductance and capacitance with a maximum of 50% of each of the values.

 

 

The intrinsically safe output circuits are safely electrically isolated from the supply circuit, the signal circuit and the input circuit up to a peak value of 375V of the nominal voltage.

 
CONDITIONS OF CERTIFICATION: NO
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx TUN 04.0001
 
Date of Issue:2007-09-10Issue No.: 1
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
The changes concern the marking, the internal configuration and the electrical data.
 
 