IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 05.0041X issue No.: 4
 
Status:
Current
 
Date of Issue:2018-06-25Page 1 of 4
 
 
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany
Equipment:Type KFD2-CD-Ex1.32-** Transformer Isolated Output Driver
 
Optional accessory:
 
Type of Protection:Intrinsic Safety

 Marking:

[Ex ia Ga] IIC
[Ex ia Da] IIIC
[Ex ia Ma] I
-20°C ≤ Ta ≤ +60°C / +70°C

 
 
Approved for issue on behalf of the IECEx
Certification Body:
R S Sinclair

 
Position:Technical Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton, Derbyshire, SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 05.0041X
 
Date of Issue:2018-06-25Issue No.: 4
 
Page 2 of 4
  
Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Additional Manufacturing location(s):
Pepperl + Fuchs Asia PTE Limited
18 Ayer Rajah Crescent
Singapore 139942
Singapore

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
IECEx ATR:File Reference:
GB/BAS/ExTR15.0023/00   15/0069  
GB/BAS/ExTR16.0291/00   16/0060  
GB/BAS/ExTR17.0314/00   17/0654  


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 05.0041X
 
Date of Issue:2018-06-25Issue No.: 4
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 
The Type KFD2-CD-Ex1.32-** Transformer Isolated Output Driver is a device designed to restrict the transfer of energy from unspecified non-hazardous area apparatus to intrinsically safe temperature sensors located in the hazardous area, and provide galvanic isolation between the hazardous and non-hazardous area circuits.

The Type KFD2-CD-Ex1.32-** Transformer Isolated Output Driver comprises a number of electrical components, including isolating transformers, fuses, resistors and zener diodes all mounted onto a single printed circuit board (PCB) and housed within a plastic enclosure with plug-in terminals.

The apparatus comes in various options which are identified by the **.
The option permits the unit to convert the input signal to output signal from current to current; current to voltage; voltage to current or voltage to voltage in any combination of the following voltage and current type:-
Output Current (** = 0 to 8): 0-20mA & 4-20mA
Output Voltage (** = 9 to 25): 0-5V, 1-5V, 0-10V & 2-10V

For apparatus parameters see data in the Annex. 


 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 

1. The safety device must be installed in a controlled environment with a pollution level limited to pollution degree 2 (or better) or be installed within an enclosure providing a degree of protection of at least IP54 according to IEC 60529 & IEC 60079-0; provision shall be made to ensure that the non-hazardous area connections are limited to overvoltage category II as defined in IEC 60664-1.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 05.0041X
 
Date of Issue:2018-06-25Issue No.: 4
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Variation 4.1

To permit the following changes:
- a new schematic and PCB layout (output parameters have been updated accordingly)
- an increase of the maximum ambient to +70°C
- minor changes to the transformer
- assessment of the PCB against IEC 60079-11 Annex F. A related specifc condition of use now applies.

ExTR: GB/BAS/ExTR17.0314/00File Reference:   17/0654
 
 