IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 10.0061X issue No.: 2
 
Status:
Current
 
Date of Issue:2018-05-10Page 1 of 4
 
 
Applicant:
Pepperl & Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany
Equipment:Transformer Isolated Potentiometer Amplifier Type KFD2-PT2-Ex1….
 
Optional accessory:
 
Type of Protection:Increased Safety

 Marking:

Ex ec IIC T4 Gc
(-20°C≤ Ta ≤ +60°C)

 
 
Approved for issue on behalf of the IECEx
Certification Body:
R. S. Sinclair

 
Position:Technical Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton, Derbyshire, SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 10.0061X
 
Date of Issue:2018-05-10Issue No.: 2
 
Page 2 of 4
  
Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Additional Manufacturing location(s):
Pepperl + Fuchs Asia PTE LTD
18 Ayer Rajah Crescent
Singapore 139942
Singapore

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-7 : 2015
Edition: 5.0
Explosive atmospheres – Part 7: Equipment protection by increased safety ''e''
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/BAS/ExTR10.0126/00GB/BAS/ExTR12.0163/00GB/BAS/ExTR18.0108/00


Quality Assessment Report:

DE/PTB/QAR06.0008/08


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 10.0061X
 
Date of Issue:2018-05-10Issue No.: 2
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The Transformer Isolated Potentiometer Amplifier Type KFD2-PT2-Ex1… is designed to enable the signal from a potentiometer located in the hazardous area to be monitored while limiting the voltage and current to intrinsically safe levels.

The Transformer Isolated Potentiometer Amplifier Type KFD2-PT2-Ex1… comprises a number of electronic components including two isolating transformers, fuses, zener diodes and resistors all mounted on a single printed circuit board and housed in a plastic enclosure.

See Annex for electrical data.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 

1.  The Transformer Isolated Potentiometer Amplifier Type KFD2-PT2-Ex1.... must be installed in a suitably certified enclosure such that it is afforded a degree of protection of at least IP54 in accordance with IEC 60079-0, IEC 60079-7 & IEC 60529 and is in an area of at least pollution degree 2.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 10.0061X
 
Date of Issue:2018-05-10Issue No.: 2
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Variation 2.1

To confirm that the equipment covered by this certificate has been reviewed against the requirements of IEC 60079-0:2011 & IEC 60079-7:2015 for Ex ec equipment and that none of these differences, with the exception of marking, affect this equipment. The equipment is now marked:

Ex ec IIC T4 Gc (-20°C≤ Ta ≤ +60°C)

,

,,,,,,,

 ExTR: GB/BAS/ExTR18.0108/00 File Reference:   17/0678
 
 




Copyright © IEC-IECEx 2019 , Geneva Switzerland. All rights reserved.