Certificate No.:
IECEx BVS 07.0019X issue No.: 1
 
Status:
Current
 
Date of Issue:2019-04-23Page 1 of 4
 
 
Applicant:
HUMMEL AG
Lise-Meitner-Straße 2
79211 Denzlingen
Germany
Equipment:Cable glands types HSK-M-Ex 1610.****.**, HSK-M-Ex 1640.****.**, HSK-M-EMV-Ex 1616.****.**, HSK-M-EMV-D-Ex 1636.****.**HSK-MZ-Ex 1611.****.**, HSK-MZ-EMV-Ex 1617.****.**HSK-INOX-Ex 1612.****.**, HSK-INOX-EMV-Ex 1672.****.**, HSK-M-Multi-Ex 1687.****.**, HSK-M-FLAKA-Ex 1689.****.**, HSK-INOX-*-Ex AB61-******
 
Optional accessory:
 
Type of Protection:Protection by Enclosure "t", Increased Safety "e"

 Marking:

Ex eb IIC Gb
Ex ta IIIC Da

 
 
Approved for issue on behalf of the IECEx
Certification Body:
Ralf Leiendecker

 
Position:Deputy Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
DEKRA Testing and Certification GmbH
Certification Body
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BVS 07.0019X
 
Date of Issue:2019-04-23Issue No.: 1
 
Page 2 of 4
  
Manufacturer:
HUMMEL AG
Lise-Meitner-Straße 2
79211 Denzlingen
Germany


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2017
Edition: 7.0
Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
IEC 60079-7 : 2017
Edition: 5.1
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

DE/BVS/ExTR07.0023/01


Quality Assessment Report:

DE/BVS/QAR07.0001/09


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BVS 07.0019X
 
Date of Issue:2019-04-23Issue No.: 1
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

Subject and Type

Cable glands
Type HSK-M-Ex 1610.****.**
Type HSK-M-Ex 1640.****.**
Type HSK-M-EMV-Ex 1616.****.**
Type HSK-M-EMV-D-Ex 1636.****.**
Type HSK-MZ-Ex 1611.****.**
Type HSK-MZ-EMV-Ex 1617.****.**
Type HSK-INOX-Ex 1612.****.**
Type HSK-INOX-EMV-Ex 1672.****.**
Type HSK-M-Multi-Ex 1687.****.**
Type HSK-M-FLAKA-Ex 1689.****.**
Type HSK-INOX-*-Ex AB61-******
Instead of the *, numbers for the definition, the thread design and the corresponding number and diameter of the cables or wires or the dimensions of the flat cable are inserted. These are not relevant for explosion protection.

Description

The cable glands (cable glands and cable glands) are designed for attachment to equipment of type of protection "Increased Safety" (Ex eb) and are used for the insertion of stationary cables and wires. The types HSK-MZ-*-Ex can also be used for cables and wires that are not fixedly installed. The cable glands can also be used in EPL Da and Db areas exposed to combustible dust.

Parameters

Permissible temperature range of the cable glands                       -20 °C to +95 °C

The ambient temperature range of the electrical equipment is usually limited to -20 °C ≤ Tamb ≤ +40 °C. The upper ambient temperature for these cable glands can exceed +40 °C if the permissible temperature range of the cable glands from -20 °C to +95 °C is observed for the respective application.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 

The cable glands with a locknut without strain relief clamp may only be used to insert permanently installed cables and wires. Only the types HSK-MZ-Ex 1611.****.** and HSK-MZ-EMV-Ex 1617.****.** have a locknut with strain relief clamp.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BVS 07.0019X
 
Date of Issue:2019-04-23Issue No.: 1
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

- Upgrading to the new standard status
- Add new types:
   • HSK-M-Ex (M20x1.5)
   • HSK-INOX-Ex (M20x1.5)

 
 