IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx FMG 09.0005X issue No.:2
 
Status:
Current
 
Date of Issue:2014-04-22 Page 1 of 4


    
Applicant:
Expro Meters, Inc.
50 Barnes Park North
Wallingford, CT 06492
United States of America


 
Equipment:Series QEX1000 ActiveSONAR Flowmeter System
Optional accessory:Consisting of Flow Transmitter, Junction Box, and Transducer Assemblies


 
Type of Protection:Ex d mb IIB T6...T4 -45C(-50C)≤Ta≤+60C Gb IP66/67


 
Marking: Flow Transmitter Assy:
Ex d IIB T6...T4 -50°C≤Ta≤+60°C Gb IP66
Junction Box Assy:
Ex d IIB T6...T4 -50°C≤Ta≤+60°C Gb IP66
Transducer Assy:
Ex mb IIB T6...T4 -45°C≤Ta≤+60°C Gb IP67
 
Approved for issue on behalf of the IECEx
Certification Body:
J. E. Marquedant

 
Position:Manager, Electrical Systems


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
FM Approvals LLC
1151 Boston-Providence Turnpike
Norwood, MA 02062
United States of America


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0005X
 
Date of Issue:2014-04-22Issue No.: 2
 
Page 2 of 4
 
 Manufacturer:
Expro Meters, Inc.
50 Barnes Park North
Wallingford, CT 06492
United States of America


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-18 : 2009
Edition: 3
Explosive atmospheres Part 18: Equipment protection by encapsulation "m"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
US/FMG/ExTR09.0011/00US/FMG/ExTR09.0011/01US/FMG/ExTR09.0011/02US/FMG/ExTR09.0011/03


Quality Assessment Report:

US/FMG/QAR09.0006/00US/FMG/QAR09.0006/01US/FMG/QAR09.0006/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0005X
 
Date of Issue:2014-04-22Issue No.: 2
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

QEX1000a-b-B ActiveSONAR Flowmeter System consisting of the following electrical sub-assemblies
a = alphanumeric string indicating general configuration and application (Not Ex safety related)
b = alphanumeric. Operational process temperature [never exceeding+125°C] (Not Ex safety related)


   TA1000-aaa-bbb-cc-de-Agh-ii-1-k-B.  Transducer Assy
   a = alphanumeric indicating pipe (Not Ex safety related)
   b = alphanumeric indicating the set of transducer components (limited to those elements listed in ECD00020)
   c = alphanumeric indicating primary transducer interface (Not Ex safety related)
   d = 1 or 2 Protective cover material
  
e = alphanumeric indicating cover features (Not Ex safety related)
   g = 1,2,3,4,5,6,7,8,9,A,B,C,D,E,F,G,H,J,K,L,M,N,P,Q,R,S,or T. Cable gland
   h = alphanumeric indicating cable length(Not Ex safety related)
   i = alphanumeric indicating language (Not Ex safety related)
   k = alphanumeric. Operational process temperature [never exceeding+125°C] (Not Ex safety related)
   

 

   JB1000-Ebc-1-e-ff-1-h-B. Junction Box Assy
   b = alphanumeric indicating non-Ex safety-related enclosure options
   c = A, B, C, or D. Ex safety-related enclosure options.
   e = alphanumeric indicating bracket (Not Ex safety related)
   f = alphanumeric indicating language (Not Ex safety related)  
  
h = alphanumeric. Operational process temperature [never exceeding+125°C] (Not Ex safety related)

 

   FT1000-aa-Ecd-Afg-hh-i-jj-1-B. Flow Transmitter Assy
   a = alphanumeric indicating software (Not Ex safety related)
   c = alphanumeric indicating non-Ex safety-related enclosure options
   d = A or B. Ex safety-related enclosure options.
   f = 1,2,3,4,5,6,7,8,9,A,B,C,D,E,F,G,H,J,K,L,M,N,P,Q,R,S,or T. Cable gland
   g = alphanumeric indicating cable length(Not Ex safety related)
   h = alphanumeric indicating electronics option(Not Ex safety related)
   i = alphanumeric indicating communication protocol (Not Ex safety related)
   j = alphanumeric indicating language (Not Ex safety related)

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 

Specific Conditions of Use:

 

1.    Special temperature measurements are required if process temperatures can exceed 100°C. See instructions in ECD00022 or ECD00062.

2.      Special gland and cable selection requirements may apply. See instructions in ECD00022 or ECD00062.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx FMG 09.0005X
 
Date of Issue:2014-04-22Issue No.: 2
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 

Issue 2:

  • Update to Edition 6 of IEC 60079-0
  • Update to Edition 3 of IEC 60079-18
  • Minor updates to product identification
  • Revisions to the multi-transducer insert assembly, not affecting Ex Safety
  • Introduction of a combined safety instruction document ECD00062 that include all of the instructions of the current ECD00022, in addition to ATEX, US, and Canada safety instruction.
  • Updates to the marking to show the new safety instruction document, update the web site, and remove the phone number.
  • Remove the “tall cover” options from the Flow Transmitter Assembly
  • Clarification of Specific Conditions of Use
  • Add reference to ECD00062 which is a compilation of IECEx, ATEX, US, and Canada instruction. It will contain all of the same information as ECD00022.
 
 








Copyright © IEC-IECEx 2017 , Geneva Switzerland. All rights reserved.