Certificate No.:
IECEx ITS 10.0015X issue No.: 2
 
Status:
Current
 
Date of Issue:2018-03-22Page 1 of 4
 
 
Applicant:
Scancon Encoders A/S
Huginsvej 8
3400 Hileroed
Denmark
Equipment:Incremental and Absolute Encoder type 2REX
 
Optional accessory:
 
Type of Protection:Flameproof enclosure 'db' and Dust 'tb'

 Marking:

IECEx ITS 10.0015X

Ex db IIC T5 Gb

Ex tb IIIC T100°C Db

-40°C < Tamb < +70°C

 
 
Approved for issue on behalf of the IECEx
Certification Body:
P Moss

 
Position:Certification officer


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
Intertek Testing & Certification Limited
ITS House, Cleeve Road,
Leatherhead,
Surrey, KT22 7SB
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 10.0015X
 
Date of Issue:2018-03-22Issue No.: 2
 
Page 2 of 4
  
Manufacturer:
Scancon Encoders A/S
Huginsvej 8
3400 Hileroed
Denmark


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2014-06
Edition: 7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/ITS/ExTR10.0008/00GB/ITS/ExTR10.0008/01GB/ITS/ExTR15.0002/00


Quality Assessment Report:

GB/EXV/QAR17.0015/00


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 10.0015X
 
Date of Issue:2018-03-22Issue No.: 2
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The Encoder Type 2REX is a small cylindrical unit (68mm in diameter with length dependent on model) containing low voltage electronic components.  The enclosure is manufactured from either aluminium, stainless steel or acid-proof stainless steel.  The enclosure comprises of cylindrical flamepaths between the End Cap & Cover Tube and Cover Tube & Housing.  The rotating shaft forms a cylindrical flamepath through the housing controlled by k & m factors and is held in place with 2 precision roller element bearings.  The enclosure has one threaded cable entry fitted with either a certified M20x1.5, M25x1.5, 1/2"NPT or 3/4"NPT cable gland or an M15 integral cable gland.  Both internal and external earthing is provided.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 

1. Minimize the risk from electrostatic discharge - clean only with a damp cloth.

2. Temperature at the cable gland or branching point could exceed 70°C or 80°C respectively - suitably rated cable must be utilized.

3. It is a condition of certification that the flamepaths have to comply with the manufacturers drawings and can only be repaired by the manufacturer.

4. The fasteners used to secure enclosure body to end shields have a minimum yield stress of 450 Mpa.

5. For models without integral cable gland use only suitably certified Ex db IIC Gb and Ex tb IIIC Db cable glands, thread adaptors and blanking elements.

6. It is a condition of certification that precautions must be taken to avoid dust from forming layers on the encoder.

 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 10.0015X
 
Date of Issue:2018-03-22Issue No.: 2
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Issue 1:

Change of address from "Tranevang 1, 3450 Alleroed, Denmark" to "Huginsvej 8, DK-3400, Hilleroed, Denmark". No other changes.

Issue 2:

1. Inclusion of new type of rotary seal.

2. Inclusion of alternative type of O-ring.

3. Update of IEC 60079-1 from Ed. 6 to Ed. 7.

4. Update of IEC 60079-31 from Ed. 1 to Ed. 2.

5. Change of QAN/QAR Issuer.

6. Minor drawing changes not compromising the IECEx cerification.

 
 