Certificate No.:
IECEx ITS 14.0035X issue No.: 2
 
Status:
Current
 
Date of Issue:2017-11-09Page 1 of 4
 
 
Applicant:
Scancon Encoders A/S
Huginsvej 8,
DK-3400,
Hilleroed
Denmark
Equipment:Blind Plugs (blanking elements) M20 and M25
 
Optional accessory:
 
Type of Protection:Flameproof 'Ex db', and Dust protection by enclosure 'Ex tb'

 Marking:

Ex db I Mb

Ex db IIC Gb 

Ex tb IIIC Db

IECEx ITS 14.0035X

 
 
Approved for issue on behalf of the IECEx
Certification Body:
Paul Moss

 
Position:Certification Officer


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
Intertek Testing & Certification Limited
ITS House, Cleeve Road,
Leatherhead,
Surrey, KT22 7SB
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 14.0035X
 
Date of Issue:2017-11-09Issue No.: 2
 
Page 2 of 4
  
Manufacturer:
Scancon Encoders A/S
Huginsvej 8,
DK-3400,
Hilleroed
Denmark


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2014-06
Edition: 7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-31 : 2013
Edition: 2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/ITS/ExTR14.0038/00GB/ITS/ExTR14.0038/01GB/ITS/ExTR14.0038/02GB/ITS/ExTR15.0002/00


Quality Assessment Report:

GB/EXV/QAR17.0015/00


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 14.0035X
 
Date of Issue:2017-11-09Issue No.: 2
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The Scancon Blind Plugs are blanking elements available in thread sizes M20 x 1.5, and M25 x 1.5, and manufactured from stainless steel.  They are to be fully tightened into threaded holes on thick-walled flameproof and dust protected enclosures to form a threaded joint such that minimum thread engagement requirements are met.

The operating temperature range is -60°C to +120°C.


 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
  • The operating temperature range is -60°C to +120°C.   The temperature locally and internally to the blind plugs when fitted into an enclosure must be taken into account, in addition to the external ambient temperature range.
  • When fitted to a non-metallic/non-conductive enclosure conformity with clause 7.5 of IEC 60079-0:2011 (Accessible metal parts) must be confirmed.
  • When used in flameproof (Ex d) applications, the wall of the flameproof enclosure into which it is fitted shall be such as to maintain at least 5.34 full threads or 8mm of engagement.
  • Blanking elements must not be used with a thread adaptor.

 

 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx ITS 14.0035X
 
Date of Issue:2017-11-09Issue No.: 2
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Issue 1:

Change of address from "Tranevang 1, 3450 Alleroed, Denmark" to "Huginsvej 8, DK-3400, Hilleroed, Denmark".  The blind plugs are small and the Scancon name is marked on the equipment but not the postal address, as permitted and in compliance with IEC 60079-0 Edition 6.0.   The address on the Installation, Operation and Maintenance Instructions has been updated.  Minor clarifications within certificate have been made by Intertek.

Issue 2:

1. Change of QAR from DE/TUN/QAR12.0002/02 to GB/EXV/QAR17.0015/00.

2. Update from IEC 60079-1:2007 Ed. 6 to IEC 60079-1:2014 Ed. 7.

3. Change of operating temperature range (from -40°C to +70°C to -60°C to +120°C).

 
 