IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx TSA 11.0008X issue No.: 2
 
Status:
Current
 
Date of Issue:2018-10-19Page 1 of 4
 
 
Applicant:
Scancon Encoders A/S
Huginsvej 8
3400 Hilleroed
Denmark
Equipment:Optical Encoder Type EXME
 
Optional accessory:
 
Type of Protection:Flameproof "d"

 Marking:

Ex db I Mb

-40°C ≤ Ta ≤ +70°C

 
 
Approved for issue on behalf of the IECEx
Certification Body:
Ujen Singh

 
Position:Quality & Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
TestSafe Australia
919 Londonderry Road
Londonderry NSW 2753
Australia


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TSA 11.0008X
 
Date of Issue:2018-10-19Issue No.: 2
 
Page 2 of 4
  
Manufacturer:
Scancon Encoders A/S
Huginsvej 8
3400 Hilleroed
Denmark


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2017
Edition: 7.0
Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-1 : 2014-06
Edition: 7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

AU/TSA/ExTR11.0044/00AU/TSA/ExTR11.0067/00AU/TSA/ExTR18.0030/00


Quality Assessment Report:

GB/EXV/QAR17.0015/01


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TSA 11.0008X
 
Date of Issue:2018-10-19Issue No.: 2
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The Optical Encoder EXME is a small flameproof construction enclosure containing the electronics. The encoder housing is manufactured from stainless steel or acid proof stainless steel with drive shaft in one enclosure end shield. The shaft can be either solid type shaft (EXME-A) or hollow type shaft (EXME-H). The drive end shield is secured to the body with six M4 counter bored socket head cap screws. The non-drive end shield is secured to the body with six M4 counter bored socket head cap screws. The body makes one cylindrical joint with the non-drive shield on one side and another cylindrical joint with the drive end shield on another side. O-rings are fitted to each cylindrical joint. There is a shaft seal on drive end shield, where two ball bearings are mounted to the cylindrical joint between the shaft and the drive end shield.

The encoder housing can be provided with one to four M20 × 1.5 – 6H, or M25 × 1.5 – 6H, or ½’’ NPT, or ¾’’ NPT threaded entries on the non drive end shield. These threaded entries are closed with the suitable separately IECEx certified cable glands. All unused entries must be closed with suitable separately IECEx certified blanking elements. The fasteners used to secure enclosure body to end shields shall have a minimum yield stress of 450 MPa. The apparatus is rated at 300 mA maximum current and voltage range from 4.5 V d.c or 10 V d.c. to 30 V d.c.. The encoder model numbers and coding is shown in the drawing 00240171. Rated speed for type variants with shaft seal maximum 3000 rpm; without shaft seal maximum 6000 rpm.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
  1. As flameproof joints parameters are different from the minimum/maximum defined in Table 2 of IEC 60079-1, the repair must be carried out only by the manufacturer in accordance with the certification drawings.
  2. The manufacturer’s instruction must be followed to minimize the risk from electrostatic discharge.
  3. For ambient temperature 65°C to 70°C, cable must be rated for at least 85°C.
  4. The fastener used to secure enclosure body to end shields shall have a minimum yield stress of 450Mpa
  5. Use only suitably certified Ex db I Mb cable glands, thread adaptors and blanking elements comply to ambient temperature range - 40°C to + 70°C and relevant IP rating -IP64/65/66/67/68 (1h/1 meter)
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TSA 11.0008X
 
Date of Issue:2018-10-19Issue No.: 2
 
Page 4 of 4
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 

Issue 1:

Address of the manufacturer was changed to Huginsvej 8, Hilleroed 3400 Denmark, from Tranevang 1, Alleroed 3450 Denmark.

 

 Issue 2:

  1. Removing Group II and Group III from certification, although still keeping Group III assessment in IECEx test report
  2. Updating certification standard from IEC 60079-0:2004 Edition 4.0 and IEC 60079-0:2007 Edition 5.0, to IEC 60079-0:2017, Edition 7.0
  3. Updating certification standard from IEC 60079-1:2007 Edition 6.0 to IEC 60079-1:2014, Edition 7.0
  4. Updating standard in IECEx test report from IEC 60079-31:2008 Edition 1.0 to IEC 60079-31:2013, Edition 2.0
  5. Change of ambient temperature from -20°C ≤ Ta ≤ +65°C to -40°C ≤ Ta ≤ +70°C
  6. Provides more options of Back Covers, increased from 2 options to totally 5 optional shapes in the product family, total number of thread entries to each Back Cover from 2 to 5; besides original M20 × 1.5 – 6H thread, more threaded entry options: M25 × 1.5 – 6H, or ½’’ NPT, or ¾’’ NPT
  7. Additional voltage range of 4.5 – 30 V d.c.
  8. Inclusion of new type of rotary seal
  9. Increase in maximum gap of both end cover cylindrical joints from 0.08mm to 0.1mm
  10. Changes to the “Specific Conditions of Use”
  11. Update of drawing set & material datasheets
 
 