Applicant:
Eltomatic A/S
Fabriksvej 6
9490 Pandrup
Denmark
Equipment:Encoder type 01-08
 
Optional accessory:
 
Type of Protection:Flameproof Enclosure, Intrinsic Safety

 Marking: Ex d+ib IIB T4 Ga
 
 
Approved for issue on behalf of the IECEx
Certification Body:
Christian Roder

 
Position:Deputy Head of the Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
TÜV NORD CERT GmbH
Hanover Office
Am TÜV 1, 30519 Hannover
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TUN 15.0035X
 
Date of Issue:2017-02-13Issue No.: 1
 
Page 2 of 5
  
Manufacturer:
Eltomatic A/S
Fabriksvej 6
9490 Pandrup
Denmark


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2014-10
Edition: 3.0
Explosive atmospheres – Part 26: Equipment with Equipment Protection Level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

DE/TUN/ExTR15.0046/00DE/TUN/ExTR15.0046/01


Quality Assessment Report:

DE/TUN/QAR10.0001/03


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TUN 15.0035X
 
Date of Issue:2017-02-13Issue No.: 1
 
Page 3 of 5
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 
The incremental shaft encoder 01-08 is designed for heavy-duty application in environments where potentially explosive atmospheres can be expected (Gas group IIB).

The electronics of the pulse generator is designed as a metallic “d” enclosure which is intended for mounting directly on the corresponding gearbox. The counter disc is built-in into the enclosure, with a corresponding optical tracking, which is activated from the gearbox by a leading-in shaft. The connection cable mounted by the manufacturer is lead into the enclosure through a cemented stopping box, which is integrated in the enclosure.

 



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
1.  Permitted range of the ambient temperature: -30 °C to +70 °C with fixed mounted cable and -25 °C to +60 °C with movable cable. 
   
2.  The encoder cable must be routed and externally fixed in such a way that it is protected from mechanical damage. 
   
3.  The encoder shaft must be driven via a coupling arrangement that allows some radial and axial movement; otherwise damage to the shaft bearings may occur. 
   
4.  The housing material excludes the allowed value of alluminium for the usage inside EPL Ga areas. The device has to be installed in such a way that no arks or sparks will occur.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TUN 15.0035X
 
Date of Issue:2017-02-13Issue No.: 1
 
Page 4 of 5
 
 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
 
Change of the type label design
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx TUN 15.0035X
 
Date of Issue:2017-02-13Issue No.: 1
 
Page 5 of 5
 
 Additional information:
 
 

Technical data 

Type variants covered:      Encoder type name:  01-08

It can be delivered with a different number of channels (1-channel, 2-channels or 3-channels) in the voltage range 5 to 12 VDC, max 100 mA.Maximum measurable rotating speed: 600 rpm

 

Electrical data

12-V Version

Supply and signal circuit in type of protection intrinsic safety Ex ia IIB only for connection to a certified intrinsic safe circuit.

maximum values: Ui = 15 V, Ii = 260 mA, Pi = 1.25 mW, Ci ≤ 30 nF, Li ≤ 35 μH

 

resp.

 

5-V Version 

Supply and signal circuit in type of protection intrinsic safety Ex ia IIB only for connection to a certified intrinsic safe circuit.

maximum values: Ui = 8 V, Ii = 260 mA, Pi = 1.25 mW, Ci ≤ 30 nF, Li ≤ 35 μH 

 

Ambient temperature range

 

-30 °C to +70 °C – with fixed mounted cable

-25 °C to +60 °C – with movable cable

 
 
 