IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BAS 13.0057X issue No.: 0

Certificate history:

 
Status:
Current
 
Date of Issue:2013-07-11Page 1 of 3
 
 
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany
Equipment:Universal Temperature Converter Type KCD2-UT2-Ex1..
 
Optional accessory:
 
Type of Protection:Intrinsic Safety

 Marking:

[Ex ia Ga] IIC (-20°C < Ta < +60°C / +70°C)
[Ex ia Da] III C (-20°C < Ta < +60°C / +70°C)
[Ex ia Ma] I (-20°C < Ta < +60°C / +70°C)

 
 
Approved for issue on behalf of the IECEx
Certification Body:
R. S. Sinclair

 
Position:General Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton, Derbyshire, SK17 9RZ
United Kingdom


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 13.0057X
 
Date of Issue:2013-07-11Issue No.: 0
 
Page 2 of 3
  
Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Additional Manufacturing location(s):
Pepperl + Fuchs (Manufacturing) PTE LTD
18 Ayer Rajah Crescent
Singapore 139942
Singapore

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

GB/BAS/ExTR13.0130/00


Quality Assessment Report:

DE/PTB/QAR06.0008/05


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BAS 13.0057X
 
Date of Issue:2013-07-11Issue No.: 0
 
Page 3 of 3
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 

The Universal Temperature Converter Type KCD2-UT2-Ex1.. is designed to transfer a signal from TC/mV, RTD (2, 3 or 4-wire) or Potentiometer in a hazardous area to unspecified apparatus located in a non-hazardous area. The hazardous area circuit is galvanically isolated from the non-hazardous area circuit using a transformer and opto-couplers and the voltage and current appearing at the hazardous area connectors are limited to intrinsically safe levels. 

The Universal Temperature Converter Type KCD2-UT2-Ex1.. comprises a number of electronic components including an isolating transformer, two opto-isolators, fuses, zener diodes and resistors all mounted on a single printed circuit board and housed in a plastic enclosure with removable terminals and PowerRail contacts. LEDs provide status indication.

 

Different versions are identified as follows:

KCD2-UT2-Ex1-*, where * is nothing for a current output or 1 for a voltage output.

 

See Annex for electrical data.



 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 

1.  The KCD2-UT2-Ex1.. must be installed in a controlled environment with suitably reduced pollution, i.e. a level of ingress protection of at least IP54. 

 




Copyright © IEC-IECEx 2019 , Geneva Switzerland. All rights reserved.