Certificate No.:
IECEx BVS 07.0019X issue No.: 0
 
Status:
Current
 
Date of Issue:2007-09-06Page 1 of 3
 
 
Applicant:
Hummel Elektrotechnik GmbH
Merklinstraße 34
79183 Waldkirch
Germany
Equipment:Cable entries type HSK-M-Ex 1610.****.**; HSK-M-EMV-Ex 1616.****.** ; HSK-M-EMV-D-Ex 1631.****.** ; HSK-MZ-Ex 1611.****.**; HSK-MZ-EMV-Ex 1617.****.**; HSK-INOX-Ex 1612.****.**; HSK-INOX-EMV-Ex 1672.****.**; HSK-M-Multi-Ex 1687.****.**; HSK-M-FLAKA-Ex 1689.****.**
 
Optional accessory:
 
Type of Protection:Equipment protection by increased safety "e"; Protection by enclosures "tD"

 Marking: Ex e II
Ex tD A20 IP68
 
 
Approved for issue on behalf of the IECEx
Certification Body:
Dr. R. Jockers

 
Position:Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BVS 07.0019X
 
Date of Issue:2007-09-06Issue No.: 0
 
Page 2 of 3
  
Manufacturer:
Hummel Elektrotechnik GmbH
Merklinstraße 34
79183 Waldkirch
Germany


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2004
Edition: 4.0
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
IEC 60079-7 : 2006-07
Edition: 4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
IEC 61241-0 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-1 : 2004
Edition: 1
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

DE/BVS/ExTR07.0023/00


Quality Assessment Report:

DE/BVS/QAR07.0001/00


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx BVS 07.0019X
 
Date of Issue:2007-09-06Issue No.: 0
 
Page 3 of 3
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 
General product information
 
The asterisks in the type designation HSK-M-Ex 1610.****.**, HSK-M-EMV-Ex 1616.****.**, HSK-M-EMV-D-Ex 1631.****.**, HSK-MZ-Ex 1611.****.**, HSK-MZ-EMV-Ex 1617.****.**, HSK-INOX-Ex 1612.****.**, HSK-INOX-EMV-Ex 1672.****.**, HSK-M-Multi-Ex 1687.****.**, HSK-M-FLAKA-Ex 1689.****.** of the cable entries will be replaced by digits to describe the colour, the thread dimensions and the accompanying diameter range of the cable.
The cable entries type are designed for the installation at electrical apparatus type of protection increased safety “e” and serve for the installation of fixed cables.
The types HSK-MZ-Ex and HSK-MZ-EMV-Ex may also be used for the installation of non fixed cables. The cable entries are suitable for the application in areas potentially hazardous by combustible gases and dusts.
 
 
Ratings
 
Permitted temperature range -20 °C ≤ Ta ≤ +95 °C


 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
Special condition for safe use
 
The cable entries type
HSK-M-Ex 1610.****.**
HSK-M-EMV-Ex 1616.****.**
HSK-M-EMV-D-Ex 1631.****.**
HSK-INOX-Ex 1612.****.**
HSK-INOX-EMV-Ex 1672.****.**
HSK-M-Multi-Ex 1687.****.**
HSK-M-FLAKA-Ex 1689.****.**
shall only be used for fixed installations.
 
The ambient temperature range of electrical apparatus is normally limited to -20 °C ≤ Ta ≤ +40 °C.
The ambient temperature range can be exceeded for the use of these cable entries as long as the permitted temperature range of -20 °C ≤ Ta ≤ +95 °C of the cable entries is taken into account.
 