IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BVS 09.0049X issue No.:1
 
Status:
Current
 
Date of Issue:2013-11-29 Page 1 of 4


    
Applicant:
G.M. International S.R.L.
Via San Fiorano 70
20852 Villasanta (MB)
Italy


 
Equipment:Multiplexer System type D2000M type Power Supply - Gateway type D2050M-***
Optional accessory:


 
Type of Protection:Equipment protection by intrinsic safety "i", Intrinsically safe electrical systems, Equipment with equipment protection level (EPL) Ga


 
Marking: [Ex ia Ga] IIC (power supply type D2050M-***)
Ex ia [ia Ga] IIC T4 Gb (field devices type:
D2030M-*** / D2010M-*** / D2011M-***)
 
Approved for issue on behalf of the IECEx
Certification Body:
H.-Ch. Simanski

 
Position:Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0049X
 
Date of Issue:2013-11-29Issue No.: 1
 
Page 2 of 4
 
 Manufacturer:
G.M. International S.R.L.
Via San Fiorano 70
20852 Villasanta (MB)
Italy


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-25 : 2010-02
Edition: 2.0
Explosive atmospheres – Part 25: Intrinsically safe electrical systems
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/BVS/ExTR09.0045/01


Quality Assessment Report:

NO/DNV/QAR07.0005/04


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0049X
 
Date of Issue:2013-11-29Issue No.: 1
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
Type Code
(No extension)

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 
1Power Supply - Gateway type D2050M-***
1.1Installation in the safe area.
1.1.1    Wiring shall satisfy the conditions of clause 6.3.12 and clause 7.6.e of IEC 60079-11:2011.
1.1.2Clearances of un-insulated conductors of intrinsically safe circuits to grounded metal parts of the enclosure shall be at least 3 mm, and to un-insulated conductors of non-intrinsically safe circuits of other apparatus shall comply with the values given in table 5 IEC 60079-11:2011 as a minimum.
1.1.3Terminals or connectors for the intrinsically safe fieldbus supply and signal circuits shall be arranged according to clause 6.2.1 or 6.2.2 of IEC 60079-11:2011 respectively.
1.2Installation in the hazardous area requiring EPL Gb.
1.2.1The Power Supply - Gateway type D2050M-*** shall be mounted in an enclosure providing a suitable type of explosion protection.
1.2.2Mounting in an enclosure providing a suitable type of explosion protection shall be submitted to separate assessment and / or certification procedure.
1.3Field wiring
For interconnection cable between Power Supply - Gateway type D2050M-*** and Field Devices type D2030M-*** and / or type D2010M-*** the cable-parameters listed in the ratings section 3 of issue 0 of the IECEx certificate apply.
2Intrinsically safe apparatus type D2030M-*** / D2010M-*** / D2011M-***
The backplane of the field devices type D2030M-*** / D2010M-*** / D2011M-*** shall be protected against electrostatic charge by means of suitable installation on DIN rails, if not mounted inside stainless steel enclosure of type series GM23xx.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 09.0049X
 
Date of Issue:2013-11-29Issue No.: 1
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Devices of Multiplexer System type D2000M have been subjected optionally to some minor changes not affecting IS parameters. The assessment of the apparatus has been carried out using the current standard version.
 
 








Copyright © IEC-IECEx 2017 , Geneva Switzerland. All rights reserved.