IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BVS 10.0022X issue No.:0
 
Status:
Current
 
Date of Issue:2010-03-08 Page 1 of 3


    
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstr. 200,
68307 Mannheim
Germany


 
Equipment:End of line unit (Terminator) type F*-F*-Ex1.D.IEC and type F*-FT-Ex1.I.IEC
Optional accessory:


 
Type of Protection:Equipment protection by flameproof enclosures "d", intrinsic safety "i", equipment protection level (EPL) Ga, Fieldbus intrinsically safe concept (FISCO)


 
Marking: Ex d IIC T6 Gb or Ex ia IIC T6 Ga
 
Approved for issue on behalf of the IECEx
Certification Body:
P. Migenda

 
Position:Deputy Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 10.0022X
 
Date of Issue:2010-03-08Issue No.: 0
 
Page 2 of 3
 
 Manufacturer:
Pepperl + Fuchs GmbH
Lilienthalstr. 200,
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE LT
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore
Pepperl + Fuchs GmbH
Lilienthalstr. 200,
68307 Mannheim
Germany
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
IEC 60079-27 : 2008
Edition: 2.0
Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO)
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/BVS/ExTR10.0032/00


Quality Assessment Report:

DE/PTB/QAR06.0007/02DE/PTB/QAR06.0008/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 10.0022X
 
Date of Issue:2010-03-08Issue No.: 0
 
Page 3 of 3
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
Description:
 
The end of line unit is used as line terminator in bus systems. It is designed to be mounted to enclosures in type of protection flameproof enclosure, increased safety or intrinsically safe apparatus (only type F*-FT-Ex1.I.IEC).
 
The end of line unit type F*-FT-Ex1.I.IEC may be connected to intrinsically safe circuits in accordance with FISCO model.
 
The end of line unit type F*-FS-Ex1.D.IEC is a variation of type F*-FT-Ex1.D.IEC and has only a fully encapsulated fuse inside the enclosure.
 
 
Subject and Type:
 
See Annex
 
 
Ratings:
 
See Annex
 
CONDITIONS OF CERTIFICATION: YES as shown below:
 
1    The end of line unit has to be securely mounted to the wall of an apparatus type of protection
      flameproof enclosure or increased safety or intrinsic safety (only type F*-FT-Ex1.I.IEC) designed for
      this purpose. The mounting conditions have to guarantee the incorporation of the unit enclosure into
      the local equipotential bonding.
 
2    Mounting of the end of line unit to increased safety enclosures have to be in such a way that the
      degrees of protection of that enclosure are maintained.
 
3    The end of line unit is designed for use in the following ambient temperature range:
      temperature class T6 -50 °C up to +60 °C
      temperature class T5 -50 °C up to +75 °C
      temperature class T4 -50 °C up to +85 °C
 
4    For the end of line unit type F*-FT-Ex1.D.IEC the following applies additionally:
 
4.1 If explosive atmosphere is present, the enclosure, to which the end of line unit is mounted, has not
      to be opened even when the supply is switched off.
 
4.2 Mounting of the end of line unit to flameproof enclosures is restricted to such enclosures with a
      reference pressure of 20 bar as a maximum.
 
5    For the end of line unit type F*-FT-Ex1.I.IEC the following applies additionally:
      Mounting of the end of line unit to the wall of an apparatus type of protection flameproof enclosure,
      increased safety or intrinsic safety the terminals of the intrinsically safe circuit have to be separated
      from those of non intrinsically safe circuits, other intrinsically safe circuits and earthed metal parts in
      accordance with clause 6.2.1 of IEC 60079-11.
 