IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BVS 12.0055X issue No.:0

Certificate history:

 
Status:
Current
 
Date of Issue:2012-11-15 Page 1 of 4


    
Applicant:
Pepperl + Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Electrical Apparatus:Electronic Remote I/O Input/Output-Device; (I/O-Device) LB3x04 *, LB3x05 *
Optional accessory:


 
Type of Protection:Equipment protection by intrinsic safety "i"; Equipment protection by type of protection "n"; Equipment with equipment protection level (EPL) Ga


 
Marking:
Standard Alternate
Ex nA [ia Ga] IIC T4 Gc      Ex nAc [ia] IIC T4
[Ex ia Da] IIIC [Ex ia] IIIC
[Ex ia Ma] I [Ex ia] I
Ex nA [ic] IIC T4 Gc Ex nAc [ic] IIC T4
 
Approved for issue on behalf of the IECEx
Certification Body:
H.-Ch. Simanski

 
Position:Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 12.0055X
 
Date of Issue:2012-11-15Issue No.: 0
 
Page 2 of 4
 
 Manufacturer:
Pepperl + Fuchs GmbH
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Singapore


 
 Additional Manufacturing location(s):
Pepperl + Fuchs PTE LTD
P+F Building, 18 Ayer Rajah Crescent
Singapore 139942
Singapore
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2010
Edition: 4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/BVS/ExTR12.0061/00


Quality Assessment Report:

DE/PTB/QAR06.0008/04


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 12.0055X
 
Date of Issue:2012-11-15Issue No.: 0
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Description

The I/O-Device type LB3x04 * / LB3x05 * is designed as associated apparatus and designated for installation in the safe area or alternatively in areas requiring EPL Gc equipment.

LB3x04 *, LB3x05 * provide the same hardware setup but different firmware.

 The l/O-devices type LB3x04 * / LB3x05 * are designated for installation on special backplanes type LB90xx * according to CoC IECEx BVS 09.0037X, fitted with power supply (power supply unit type LB9006 * / type LB9104 *).

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

General:

- the devices must only be used together with the respective backplanes

- along the IS-circuits equipotential bonding must be achieved.

 

Installation in the safe area:

The devices must be installed

- in an enclosure complying with IEC 60079-0 providing degree of IP protection IP54 according to IEC 60529, or

- in a controlled environment providing pollution degree 2 according to IEC/EN 60664-1.

 

Installation in areas requiring EPL Gc equipment (Zone 2):

The devices must be installed in an enclosure corresponding at least to EPL Gc according IEC 60079-0 and providing degree of IP protection IP54 according to IEC 60529.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 12.0055X
 
Date of Issue:2012-11-15Issue No.: 0
 
Page 4 of 4
 
 
EQUIPMENT(continued):
 

General product information:

Electronic components of the l/O-device are arranged on printed-circuit-boards (PCB) packaged in a Polycarbonate housing suitable for installation on special backplanes.

 

The front of the l/O housing show to 8 pole sockets inputs or outputs. These are connected via plug in connectors with side screw or front screw or cage clamp wire fasteners.

 

The l/O-device provides safe galvanic seperation between intrinsically safe circuits and non-ontrinsically safe signal circuits / non-intrinsically safe power supply on the PCB up to a sum of peak values of rated voltages of 375 V (type LB3104 * / LB3105 *) or according to level of requirements 'ic' as a minimum (type LB3004 * / LB3005 *).

 

Various versions of the l/O-device provide different level of IS protection:

 

-type LB3104 * / LB3105 *; up to four active output / passive input circuits that can be used to supply 2-wire or 3-wire transmitter circuits and/or analouge inputs for measurement purposes; level of IS protection Ex ia llC / Ex ia l / Ex ia lllC

 

- type LB3004 * / LB3005 *; up to four active output / passive input circuits that can be used to supply 2-wire or 3-wire transmitter circuits and/or analouge inputs for measurement purposes; level of IS protection Ex ia llC

 

The up to four active output / passive input circuits are not galvanically seperated of each other (common ground)





Type Code of LB-devices providing external circuits tpe or protection IS

I/O-Device type LB3x04 +, LB3x05 *.
(In the full designation the "x" is replaced by numbers "0" or "1" an the "*" by letters and numbers marking non ex-relevant details).



Parameters