IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx BVS 14.0111X issue No.:1
 
Status:
Current
 
Date of Issue:2016-02-04 Page 1 of 4


    
Applicant:
G.M. International S.R.L.
Via Mameli 53/55
20852 Villasanta (MB)
Italy


 
Equipment:Digital Output Driver type D5040* or D5040*-xxx / D5240T or D5240T-xxx
Optional accessory:


 
Type of Protection:Equipment protection by intrinsic safety "i", Equipment protection by type of protection "n"


 
Marking: Ex nA [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
 
Approved for issue on behalf of the IECEx
Certification Body:
Dr. F. Eickhoff

 
Position:Deputy Head of Certification Body


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum
Germany


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 14.0111X
 
Date of Issue:2016-02-04Issue No.: 1
 
Page 2 of 4
 
 Manufacturer:
G.M. International S.R.L.
Via Mameli 53/55
20852 Villasanta (MB)
Italy


 
 Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition: 6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2010
Edition: 4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
DE/BVS/ExTR14.0106/01


Quality Assessment Report:

NO/DNV/QAR07.0005/06


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 14.0111X
 
Date of Issue:2016-02-04Issue No.: 1
 
Page 3 of 4
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 
Type Code:
Digital Output Driver type D5040* or D5040*-xxx / D5240* or D5240*-xxx
In the full designation the "*" is replaced by letters marking details of construction as follows:
S = single channelS-xxx = single channelD5040* only
D = dual channelD-xxx = dual channel
T = triple channelT-xxx = triple channelD5240* only
Option 'xxx' = non Ex-relevant details of construction or function


Description
Electronic components of the Digital Output Driver models are arranged on printed-circuit-boards (PCB) packaged in plastic enclosures, suitable for installation on T35 DIN Rails.
The Digital Output Drivers provide fully floating single, dual or triple channel intrinsically safe power supply for solenoid valves, visual or audible alarm devices located in hazardous areas driven by control-signals generated in the safe area.
Digital Output Driver type D5040* or D5040*-xxx providing single or dual channel configuration:
For each channel two basic outputs are selectable (output A or B) with different safety parameters.
The basic outputs of the same channel can be used 'exclusive-or' only.
In addition, the basic outputs A and/or B of the two channels of dual channel model D5040D or D5040D-xxx may be interconnected in parallel for single channel operation. See 'Ratings' for permissible combinations.
Digital Output Driver type D5240T or D5040T-xxx providing three channel configuration:
For each channel three basic outputs are selectable (output A or B or C) with different safety parameters.
The basic outputs of the same channel can be used 'exclusive-or' only.
In addition, the basic outputs A, B and/or C of the three channels may be interconnected in parallel for dual or single channel operation. See 'Ratings' for permissible combinations.
The intrinsically safe output circuits provide safe galvanic separation from the non-intrinsically safe circuits on the PCB up to a sum of peak values of rated voltages of 375 V.  
Listing of all components used referring to older standards: N / A


Ratings
See Annex

 
SPECIFIC CONDITIONS OF USE: YES as shown below:
 
1. Group I application:
The Digital Output Driver shall be installed outside the hazardous area or alternatively in an enclosure providing a suitable type of protection according to separate certification.
2. Group II application:
The Digital Output Driver shall be installed:
- outside the hazardous area, or
- shall be mounted inside an enclosure, which is in accordance with IEC 60079-15 in case of alternative installation in areas requiring EPL Gc equipment.
3. Group III application:
The Digital Output Driver shall be installed outside the hazardous area or alternatively in an enclosure providing a suitable type of protection according to separate certification.
4. General:
The installation of the Digital Output Driver shall be carried out in such a way that the clearances of un-insulated conductors of intrinsically safe circuits to grounded metal parts of the enclosure are at least 3 mm, and un-insulated conductors of non-intrinsically safe circuits of other apparatus are situated at least 50 mm from terminals for external intrinsically safe circuits, or are separated from them by an insulating barrier according to clause 6.2.1 of
IEC 60079-11:2011.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx BVS 14.0111X
 
Date of Issue:2016-02-04Issue No.: 1
 
Page 4 of 4
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Electrical parameters listed in Rating
 
1. Non intrinsically safe power supply circuit
Pn has been subjected to correction from power dissipation parameters to power consumption parameters.
This correction does not affect parameters of intrinsically safe circuits.
 
2. Intrinsically safe output circuits
Po value in table 2.3.2 (Output A+C) has been subjected to slight correction.
 
3. Update of some descriptive documents
 
 
 








Copyright © IEC-IECEx 2017 , Geneva Switzerland. All rights reserved.