Certificate No.:
IECEx KEM 09.0088X issue No.:1
 
Status:
Current
 
Date of Issue:2011-03-30 Page 1 of 5


    
Applicant:
Pepperl+Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
Electrical Apparatus:Surge Protector Type D*-LBF-*
Optional accessory:


 
Type of Protection:Ex i and Ex n


 
Marking: Ex ia [ia Ga] IIC T4...T6 Gb
Ex ic IIC T4...T6 Gc
Ex nA IIC T4...T6 Gc
 
Approved for issue on behalf of the IECEx
Certification Body:
C.G. van Es

 
Position:Certification Manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

 Certificate issued by:
DEKRA Certification B.V.
Utrechtseweg 310
6812 AR Arnhem
The Netherlands
All testing, inspection, auditing and certification activities of the former KEMA Quality are an integral part of the DEKRA Certification Group.


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx KEM 09.0088X
 
Date of Issue:2011-03-30Issue No.: 1
 
Page 2 of 5
 
 Manufacturer:
Pepperl+Fuchs GmbH
Lilienthalstrasse 200
68307 Mannheim
Germany


 
 Additional Manufacturing location(s):
 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2007-10
Edition: 5
Explosive atmospheres - Part 0:Equipment - General requirements
IEC 60079-11 : 2006
Edition: 5
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2005-03
Edition: 3
Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking of Type of Protection "n" electrical apparatus
IEC 60079-26 : 2006
Edition: 2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
IEC 60079-27 : 2008
Edition: 2.0
Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO)
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:
NL/KEM/ExTR10.0036/01


Quality Assessment Report:

DE/PTB/QAR06.0007/02


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx KEM 09.0088X
 
Date of Issue:2011-03-30Issue No.: 1
 
Page 3 of 5
 
 
Schedule
 
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
 

Surge Protectors series D*-LBF-* serve as transient suppressors in the lines of electronic circuits.

This approval applies to the following equipment: 
Base units Type DB-LBF-I1 and Type DB-LBF-I1.I and modules Type DP-LBF-I1.36.DE and Type
DP-LBF-I1.36.IE

 
CONDITIONS OF CERTIFICATION: YES as shown below:
 

Ambient temperature range:
-50 °C to +50 °C for T6;
-50 °C to +75 °C for T5;
-50 °C to +80 °C for T4.

The dielectric strength of at least 500 V of the intrinsically safe circuits of the Surge Protector series
D*-LBF-* is limited only by the overvoltage protection. Terminals X5, X6, X7 and X8 are considered to be connected to earth.

For use in type of protection Ex nA IIC T4...T6 Gc:
The Surge Protector series D*-LBF-* shall be installed into an enclosure, which meets the requirements of a recognized type of protection, in accordance with IEC 60079-0.

 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx KEM 09.0088X
 
Date of Issue:2011-03-30Issue No.: 1
 
Page 4 of 5
 
 
EQUIPMENT(continued):
 
Electrical data

Module input circuits (terminals X1, X2, X5 and X6):
Un = 33 V; In = 500 mA.

Module input circuits (terminals X1, X2, X5 and X6):
in type of protection intrinsic safety Ex ia IIC, for connection to a certified intrinsically safe circuit, with the following maximum values:
Ui = 30 V; Ii = 500 mA; Pi = any; Ci = 0 nF; Li = 0 mH;

or in type of protection intrinsic safety Ex ia IIC for connection to a certified intrinsically safe circuit or a circuit in accordance with FISCO, with the following maximum values:
Ui = 17.5 V; Ii = 380 mA; Pi = 5.32 W; Ci = 0 nF; Li = 0 µH;

or in type of protection intrinsic safety Ex ic IIC, for connection to an intrinsically safe circuit, with the following maximum values:
Ui = 33 V; Ii = 500 mA; Pi = any; Ci = 0 nF; Li = 0 mH.

Module output circuits terminals X3, X4, X7 and X8):
The values of Uo, Io and Po are determined by the parameters of the circuit(s) to which the Surge Protector series D*-LBF-* is connected.
 
 
 


- PAGE BREAK -

IECEx Certificate
of Conformity

 
Certificate No.:IECEx KEM 09.0088X
 
Date of Issue:2011-03-30Issue No.: 1
 
Page 5 of 5
 
 
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
 
Issue 1: Editorial changes of test report and certificate.
 
 








Copyright © IEC-IECEx 2016 , Geneva Switzerland. All rights reserved.