IECEx CoC Home > Certified Equipment Scheme > Certificate of Conformity
important information !
an IECEx Guest User | ExCB Login

leftca_pagelinks
IECEx Certificate
of Conformity

 
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

 
Certificate No.:
IECEx NEM 14.0007X issue No.: 0

Certificate history:

 
Status:
Current
 
Date of Issue:2014-02-13Page 1 of 4
 
 
Applicant:
Moflash Signalling Ltd
Unit 18 Klaxon Industrial Estate, Tyseley, Birmingham B11 2HA
United Kingdom
Equipment:Explosion-Proof Alarm Beacon & Light
 
Optional accessory:
 
Type of Protection:Ex d

 Marking: Ex d IIC T4(Tamb=-40°C ~ +70°C)T5(Tamb=-40°C ~ +60°C)T6 (Tamb= -40°C ~ +55°C)Gb.
Ex tb III C T135°C T4(Tamb=-40°C ~ +70°C)T100°C(Tamb=-40°C ~ +60°C) T85°C (Tamb= -40°C ~ +55°C) IP66.
 
 
Approved for issue on behalf of the IECEx
Certification Body:
Asle Kaastad

 
Position:Certification manager


 
Signature:
(for printed version)
 
Date:
 
 
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
 

  Certificate issued by:
NEMKO
Gaustadelleen 30
Oslo N-0314
Norway


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx NEM 14.0007X
 
Date of Issue:2014-02-13Issue No.: 0
 
Page 2 of 4
  
Manufacturer:
Moflash Signalling Ltd
Unit 18 Klaxon Industrial Estate, Tyseley, Birmingham B11 2HA
United Kingdom


 
Additional Manufacturing location(s):

 

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended.


STANDARDS:
The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards:

 
IEC 60079-0 : 2011
Edition: 6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2007-04
Edition: 6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-31 : 2008
Edition: 1
Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure 't'
 
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above.


 
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

 
Test Report:

CN/CQM/ExTR13.0038/00NO/NEM/ExTR14.0008/00


Quality Assessment Report:

GB/SIR/QAR14.0001/00


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx NEM 14.0007X
 
Date of Issue:2014-02-13Issue No.: 0
 
Page 3 of 4
 
Schedule
 EQUIPMENT:
Equipment and systems covered by this certificate are as follows
 
 
This certificate covers Beacon light of with enclosures made of two different materials. BC-125 is stainless steel and BC-150 is GRP. The product is made up of; Main body and front-cover, connected together by a spigot joint. A glass dome is installed in the front-cover by using a cemented joint. Inside the enclosures it`s installed different PCB, terminals and light sources.  

Type Designation
BC Series – 125/ 150.


Electrical Ratings
Voltage ≤48 VDC, 100 ~ 240VAC (50/60Hz), ≤25W

 
ProductAmbient temperatureMarking
BC 125 / 150Tamb=-40°C ~ +70°CEx d IIC T4 Gb.Ex tb III C T135°C  IP66
Tamb=-40°C ~ +60°CEx d IIC T5 Gb.Ex tb III C T100°C  IP66
Tamb=-40°C ~ +55°CEx d IIC T6 Gb.Ex tb III C T85°C  IP66
 


 SPECIFIC CONDITIONS OF USE:   YES as shown below:
 
 
Repairs of the flameproof joints must be made in compliance with the structural specifications provided by the manufacturer. Repairs must not be made on the basis of values specified in tables 1 and 2 of EN/IEC 60079-1.
 


- PAGE BREAK -

IECEx Certificate
of Conformity

  
Certificate No.:IECEx NEM 14.0007X
 
Date of Issue:2014-02-13Issue No.: 0
 
Page 4 of 4
 
 EQUIPMENT(continued):
 
 
Routine Test
 A routine pressure test according to EN 60079-1 clause 16 shall be carried out on all enclosures with the following pressures:
BC 125-1.2MPa
BC 150-1.2MPa
 
 




Copyright © IEC-IECEx 2019 , Geneva Switzerland. All rights reserved.